10-48
Catalyst 2960 and 2960-S Switches Software Configuration Guide, Release 15.0(1)SE
OL-26520-01
Chapter 10 Configuring IEEE 802.1x Port-Based Authentication
Configuring 802.1x Authentication
Configuring Periodic Re-Authentication
You can enable periodic 802.1x client re-authentication and specify how often it occurs. If you do not
specify a time period before enabling re-authentication, the number of seconds between attempts
is 3600.
Beginning in privileged EXEC mode, follow these steps to enable periodic re-authentication of the client
and to configure the number of seconds between re-authentication attempts. This procedure is optional.
To disable periodic re-authentication, use the no authentication periodic interface configuration
command. To return to the default number of seconds between re-authentication attempts, use the no
authentication timer interface configuration command.
This example shows how to enable periodic re-authentication and set the number of seconds between
re-authentication attempts to 4000:
Switch(config-if)# authentication periodic
Switch(config-if)# authentication timer reauthenticate 4000
Command Purpose
Step 1
configure terminal Enter global configuration mode.
Step 2
interface interface-id Specify the port to be configured, and enter interface configuration mode.
Step 3
authentication periodic Enable periodic re-authentication of the client, which is disabled by
default.
Note The default value is 3600 seconds. To change the value of the
reauthentication timer or to have the switch use a
RADIUS-provided session timeout, enter the authentication
timer reauthenticate command.
Step 4
authentication timer {{[inactivity |
reauthenticate]} {restart value}}
Set the number of seconds between re-authentication attempts.
The authentication timer keywords have these meanings:
• inactivity—Interval in seconds after which if there is no activity from
the client then it is unauthorized
• reauthenticate—Time in seconds after which an automatic
re-authentication attempt is be initiated
• restart value—Interval in seconds after which an attempt is made to
authenticate an unauthorized port
This command affects the behavior of the switch only if periodic
re-authentication is enabled.
Step 5
end Return to privileged EXEC mode.
Step 6
show authentication interface
interface-id
Verify your entries.
Step 7
copy running-config startup-config (Optional) Save your entries in the configuration file.