22-12
Catalyst 2960 and 2960-S Switches Software Configuration Guide, Release 15.0(1)SE
OL-26520-01
Chapter 22 Configuring Dynamic ARP Inspection
Configuring Dynamic ARP Inspection
To return to the default rate-limit configuration, use the no ip arp inspection limit interface
configuration command. To disable error recovery for dynamic ARP inspection, use the no errdisable
recovery cause arp-inspection global configuration command.
Performing Validation Checks
Dynamic ARP inspection intercepts, logs, and discards ARP packets with invalid IP-to-MAC address
bindings. You can configure the switch to perform additional checks on the destination MAC address,
the sender and target IP addresses, and the source MAC address.
Step 5
errdisable recovery cause
arp-inspection interval interval
(Optional) Enable error recovery from the dynamic ARP inspection
error-disable state.
By default, recovery is disabled, and the recovery interval is 300
seconds.
For interval interval, specify the time in seconds to recover from the
error-disable state. The range is 30 to 86400.
Step 6
exit Return to privileged EXEC mode.
Step 7
show ip arp inspection interfaces
show errdisable recovery
Verify your settings.
Step 8
copy running-config startup-config (Optional) Save your entries in the configuration file.
Command Purpose

Table of Contents

Other manuals for Cisco CATALYST 2960

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco CATALYST 2960 and is the answer not in the manual?

Cisco CATALYST 2960 Specifications

General IconGeneral
ManageableYes
StackingNo
ModelCatalyst 2960 Series Switches
Power over Ethernet (PoE)Available on some models (IEEE 802.3af)
VLANs255 active VLANs
FeaturesQoS
Operating Temperature32 to 113°F (0 to 45°C)
Relative Humidity10% to 85% non-condensing
Power ConsumptionVaries by model (30W to 400W)

Related product manuals