Configuring the PVC2300 and WVC2300 Cameras
Applications > Event
Cisco PVC2300 and WVC2300 Internet Video Cameras with Audio Administration Guide 93
8
- Input 1/2—Describes the states that the input(s) must be in for an event
to be triggered. Only one input can be used. Also, note that the states for
all the inputs used must first be reached before the event will be
triggered.
- Motion Detection—Movement in a motion detection window can be
used to trigger events.
Action(s)—Select one or more actions to perform once a trigger event
occurs. Choose from the following options:
- E-mail—If checked, an e-mail with attachments (image or video) will be
delivered to the SMTP server when an alert is detected. E-mail alerts
require pre-configured e-mail settings in the Applications > Mail window.
See Applications > Mail” on page 83.
- FTP—If checked, an FTP upload with attachments (image or video) will
be activated to the FTP server when an alert is detected. A secondary
server may also be specified, if required. This will be used if the primary
server is unavailable. FTP alerts require pre-configured FTP settings in
the Applications > FTP window. See Applications > FTP” on page 86.
- SMB/CIFS—If checked, attachments (image or video) are uploaded to
the NAS device defined in the Applications > SMB/CIFS window when
an alert is detected. See Applications > SMB/CIFS” on page 102.
The following SMB/CIFS settings are visible when SMB/CIFS is enabled:
- Enable SMB/CIFS—Check the box to enable SMB/CIFS alerts. Alerts
are recorded and sent to the NAS device (SMB/CIFS server).
- Upload Path—Enter the folder name to upload alert notification to a
NAS device (SMB/CIFS server).
- Login Name—Enter the users login name for the NAS device
(SMB/CIFS server).
- Password—Enter the user password for the NAS device
(SMB/CIFS server).
- Output 1/2—If checked, the output port(s) state will be activated when
an alert is detected. Output port(s) alerts require pre-configured I/O port
setting in the Applications > I/O Ports window. See Applications > I/O
Ports” on page 96.
- Instant Messaging—If checked, an instant message will be delivered to
the Jabber server when an alert is detected. Jabber alerts require pre-