Group 19, Motor Controls
19-2-14 • Control Programming SM 765, Sep ’06
SUBMENU "SET OPTIONS"
1 HOUR METER TRUCK
RUNNING: The meter registers when the "key" is ON
KEY ON: The meter registers travel time only.
2 SET TEMPERATURE
DIGITAL: A digital (ON/OFF) motor thermal sensor is connected to F6 input.
ANALOG: An analog motor thermal sensor is connected to F6(the curve can be customized on customer
request).
None: No motor sensor switch connected.
3 THERMO PROTECTION
ON: When motor winding temperature is over 90°…, reduce the torque
OFF: Always pull torque should be provided.
4 HOUR METER TRUCK
ON: Equipment usage time should be shared between travel and hydraulic controller.
OFF: Equipment usage time should not be shared.
5 PRESSURE FUNCT
ON: Use pressure sensor to operate steering motor.
OFF: Operate steering motor by ahead/astern lever without pressure sensor.
6 DIGITAL LIFT
ON: Operate lift without potentiometer(operated by ON/OFF switch)
OFF: Lift speed is relative to the output value of potentiometer.