22
NOTE
Refer to the “ELECTRICAL CONNECTIONS” section in this manual.
To test run the Handilift:
1) Turn the car key switch ON (if equipped).
2) To operate the lift in the UP direction, press and hold the UP Button or one of the
numbered buttons.
3) Check that the lift is running clear of all parts and obstructions and has proper clearan
from the shaft walls.
ces
DO NOT USE A POWER GRINDER TO ATTEMPT TO
.
SMOOTH OUT THE RAIL JOINTS
WHEN INSTALLATION
WITH A CLEAN RAG AN
GREASE. DON’T USE M
IS COMPLETED, WIPE RAILS
D RE-LUBRICATE THEM WITH
OTOR OIL OR HEAVY GREASE.
) Take the lift to the top landing and make sure the limit switches stop the lift there. If the
e Upper Limit Switch Assembly (up or
5) Lower Limit Switch Assembly stops the lift either in
following ways:
a) Stops the lift level with the floor (in pitted installation)
OR
or (if provided) has not activated when the
ure that the under-platform sensor pan is not
mp gradient is correct for easy access from
lowly to
4
lift does not stop level with the floor, adjust th
down), as required.
Take the lift down and check that the
one of the
b) If the under-platform obstruction sens
platform is at the lower level, ens
touching the floor. Ensure that the ra
lower level(s) and that the ramp lowers s the landing.
NOTE
Befo re commencing "FINAL MECHANICAL INSTALLATION", the installer may choose to read
the " tion ELECTRICAL CONNECTIONS" section to perform wiring in preparation for the installa
of landing doors/gates and locks.
DO NOT RUN THE PLATFORM DOWN PAST THE
LOWER LIMIT SWITCHES OR THE SLING WILL BECOME
WEDGED INTO THE PIT CHANNEL. IF THIS OCCURS,
THE LIFT MUST BE HAND-CRANKED UP TO FREE IT.