Chapter 7 Parameters
68
3. The actual action time is the time it takes to drop
from FA48 or current motor speed to FA49, and
taking the minimum value.
49
The
working
speed of the
mechanical
brake when
the motor
rotates
1. It defines the speed value from motor current
cut-off to mechanical brake action (output terminal
BRK from ON to OFF) during motor working.
2.The actual action time is the time it takes to drop
from FA48 or current motor speed to FA49, and
taking the minimum value.
0-3000
r/min
100
50
Speed limit
in torque
control
mode
1:In torque control mode, the motor running speed
is limited in the range of this parameter.
2:It can prevent over speed in light load.
0-5000
r/min
3000
53
Servo
force
enable
To set :
0: The enable signal is controlled by SON of digital
input(DI).
1:Software force to servo on.
0-1
0
54
The delay
closing
time of
servo
enable
It defines the time to delay cutting off the motor
current after the servo enable signal is turned off.
0-30000ms
0
No.
Name
Function
Rang
Default
Value
55
Effective
level
control
word of
input
terminals
1.To reverse the input terminals. For unreversed
terminals, it is valid when the switch is closed,
while it is invalid when the switch is open. For
reversed terminals, it is invalid when the switch
is closed, while it is valid when the switch is open.
2.Represented by a binary digit of 4 bits. If it is
0000-1111
0000