Chapter 7 Parameters
89
position
instruction 2
F4-7
The move
speed of
internal
position
instruction 2
To set the move speed of internal position instruction 2.
0-5000
r/min
1000
F4-8
The position
cycles of
internal
position
instruction 3
To set the position cycles of the third stage internal
position instruction.
-30000-
30000
0
F4-9
The pulse
number
setting in
position loop
of internal
position
instruction 3
1. To set the position pulses of the third stage
internal position.
2. Internal position instruction 3=the position
cycles setting of the third internal position+the
pulse number setting of the third internal position.
+/-max.
cnt/rev
0
F4-10
The move
speed of
internal
position
instruction 3
To set the move speed of internal position
instruction 3.
0-5000
r/min
1000
F4-11
The number
of position
cycles of
internal
position
instruction 4
To set the number of position cycles of the fourth
stage internal position.
-30000-
30000
0