282813
LUBRICATION
Carbonator pump(s) motor(s) must be lubricated as instructed.
ADJUSTMENTS
CARBONATED WATER FLOW RATE
The black carbonated water flow regulators (see applicable Figure 2 or 3 and 7 ), which control carbonated
water flow rate into product blender tanks, are factory adjusted and normally do not require further adjustment.
If adjustment should become necessary, adjust as instructed in the SERVICE AND MAINTENANCE section.
CO
2
REGULATORS
Primary CO
2
Regulator.
The primary CO
2
regulator (see applicable Figure 2 or 3) regulates CO
2
pressure to the soft drink tanks (also
to the bag-in-box syrup system if used) and also to the secondary CO
2
regulators located inside the Unit. If
necessary to adjust the primary CO
2
regulator, adjust as instructed in the SERVICE AND MAINTENANCE
section.
Secondary CO
2
Regulators.
The secondary CO
2
regulators (see applicable Figure 2 or 3 and 7) regulate CO
2
pressure to the carbonator(s)
and product blender tanks. If necessary to adjust secondary CO
2
regulators, adjust as instructed in the
SERVICE AND MAINTENANCE section.
ADJUSTING BEATERS MOTORS CURRENTS
Beaters motors currents must be adjusted as instructed in the SERVICE AND MAINTENANCE section.
PROGRAMMING MAIN MENU SELECTIONS ONTO MESSAGE DISPLAY
The MAIN MENU SELECTIONS (see 4) may be brought up on message display as instructed in the SERVICE
AND MAINTENANCE section.
SETTING ‘‘CLOCK’’ (TIME OF DAY)
NOTE: ‘‘CLOCK’’ (TIME OF DAY) must be programmed into Unit before ‘‘DEFROST’’ (AUTOMATIC),
‘‘SLEEP’’ (SLEEP TIME), and ‘‘WAKE UP’’ (WAKE UP TIME) can be programmed into the Unit.
Program ‘‘CLOCK’’ (TIME OF DAY) into Unit as instructed in the SERVICE AND MAINTENANCE section.
PROGRAMMING ‘‘DEFROST’’ (AUTOMATIC) SETTINGS INTO UNIT
The automatic defrost system may be programmed into the Unit to occur up to nine different times during a day
with a minimum of two hours between defrost time settings. Program automatic defrost time settings into the
Unit as instructed in the SERVICE AND MAINTENANCE section.