1. Refer to PROGRAMMING MENU SELECTIONS ON MESSAGE DISPLAY and bring up ‘‘VIS READ’’ of
product in freeze cylinders.
2. Press ‘‘DEFROST’’ (SELECT) switch to bring up actual viscosity readout of product in each freeze cylinder.
3. Press ‘‘ERROR RESET’’ switch two times to exit from MENU SELECTIONS.
DISPLAYED EVAPORATOR REFRIGERATION COILS INLETS AND COMMON OUTLET
SENSORS TEMPERATURES.
Evaporator refrigeration coils inlet and common outlet temperature readings in degrees Fahrenheit may be
displayed on message displays as follows:
1. Refer to PROGRAMMING MENU SELECTIONS ON MESSAGE DISPLAY and bring up ‘‘SENSORS’’
(TEMPERATURES READOUT) on message display.
2. Press ‘‘DEFROST’’ (SELECT) switch to bring up evaporator refrigeration coils inlet and common outlet
temperature readings in degrees Fahrenheit.
Left ReadingRefrigeration Coils Inlet No. 1
Middle ReadingRefrigeration Coils Inlet No. 2
Right ReadingCommon Outlet
3. Press ERROR RESET’’ switch two times to exit from MENU SELECTIONS.
‘‘VOLTAGE’’ (DISPLAYED VOLTAGE READOUT)
Displayed voltage readout may be displayed on message display as follows:
1. Refer to PROGRAMMING MENU SELECTIONS ON MESSAGE DISPLAY and bring up ‘‘VOLTAGE’’
(DISPLAYED VOLTAGE READOUT) on message display.
2. Press ‘‘DEFROST’’ (SELECT) switch to bring up voltage readout on message display.
3. Press ‘‘ERROR RESET’’ switch two times to exit from MENU SELECTIONS.
PROGRAMMING COMPONENTS ‘‘DIAGNOSE’’ (DIAGNOSTIC MODE) INTO UNIT
‘‘DIAGNOSE’’ (DIAGNOSTIC MODE) may be programmed into the Unit to check certain components for
operation. Program ‘‘DIAGNOSE’’ into Unit and check components for proper operation as follows:
1. Refer to PROGRAMMING MAIN MENU SELECTIONS ONTO MESSAGE DISPLAY and bring up the word
‘‘CLOCK’’ on display.
2. Press ‘‘CANCEL DEFROST’’ (ADVANCE) switch to bring up ‘‘DIAGNOSE’’ menu on message display.
Press ‘‘DEFROST’’ (SELECT) switch to lock in place. The word ‘‘MOTOR 1’’ will appear on message
display.
3. Press ‘‘DEFROST’’ (SELECT) switch. No. 1 beater motor will start and operate while switch is pressed.
4. Press ‘‘CANCEL DEFROST’’ (ADVANCE) switch to advance and bring up the word ‘‘MOTOR 2’’ on
message display.
5. Press ‘‘DEFROST’’ (SELECT) switch. No. 2 beater motor will start and operate while switch is pressed.
6. Press ‘‘CANCEL DEFROST’’ (ADVANCE) switch to advance and bring up ‘‘DEFROST 1’’ on message
display.