722813
Trouble RemedyProbable Cause
FREEZE CYLINDER DOES
NOT REFILL AT ALL TIMES
WHEN DISPENSING.
A. ‘‘AUTO BLEND 1’’ or ‘‘AUTO
BLEND 2’’ switch not pressed.
A. Press ‘‘AUTO BLEND 1’’ or
‘‘AUTO BLEND 2’’ switch.
B. Carbonator water pump not
operating.
B. Check carbonator and restore to
operation.
C. Lines restricted. C. Sanitize Unit as instructed.
FROZEN PRODUCT
CONSISTENCY VARIES
EXCESSIVELY.
A. Dispensed product Brix
varying because:
Syrup and/or water flow
regulator sticking.
a.Clean regulator(s).
Primary CO
2
regulator pressure
insufficient.
b.Primary CO
2
regulator must be
adjusted from 80 to 100 psi.
B. Cylinder freeze-up causing ice
formation in center of cylinder
and liquid product channels
around ice formation.
D. Refer to CYLINDER FREEZE-UP.
NOTE: DEFROST AFFECTED FREEZE CYLINDER AS
INSTRUCTED.
CYLINDER FREEZE-UP. A. Dispensed product Brix too
low.
A. Refer to Brix (Water-to-Syrup)
‘‘Ratio’’ too low.
B. Viscosity of dispensed product
not properly adjusted.
B. Adjust dispensed product
viscosity as instructed.
ACCESSORIES AND TOOLS
ACCESSORIES
1155 Installation Kit
511005000 Cup Holder
511006000 Cup Holder
511035000 CO
2
Changeover Kit
1040 Seal Kit, Rear O-Ring Housing and O-Rings
GENERIC FLAVOR TABS
1085 Cola
1086 Cherry
1087 Orange
1088 Grape
1089 Lemon-Lime
1090 Strawberry
1091 Banana
SERVICE TOOLS
281884000 3 gallon Sanitizing Tank
322859000 Spanner Wrench, Dispensing Valve
511004000 Refractometer, 030 Scale