disabled when the system is in alarm.
Option 2 Pendant causes Immediate Panic - This option allows the Radio key to cause an immediate Panic
alarm.
Option 3 Pendant causes Delayed Panic - This option allows the radio key to cause a Panic alarm after the
button has been held on for longer than 1.5 seconds.
USER GROUPS 1-20 RADIO PENDANT TYPE P261E-P280E
P261E User Group #1 Radio Pendant Type - Default 0 OPTIONS
P262E User Group #2 Radio Pendant Type - Default 0 0 = Generic Pendant
P263E User Group #3 Radio Pendant Type - Default 0 1 = Crow Freelink
P264E User Group #4 Radio Pendant Type - Default 0 21 = Ness
P265E User Group #5 Radio Pendant Type - Default 0
P266E User Group #6 Radio Pendant Type - Default 0
P267E User Group #7 Radio Pendant Type - Default 0
P268E User Group #8 Radio Pendant Type - Default 0
P269E User Group #9 Radio Pendant Type - Default 0
P270E User Group #10 Radio Pendant Type - Default 0
P271E User Group #11 Radio Pendant Type - Default 0
P272E User Group #12 Radio Pendant Type - Default 0
P273E User Group #13 Radio Pendant Type - Default 0
P274E User Group #14 Radio Pendant Type - Default 0
P275E User Group #15 Radio Pendant Type - Default 0
P276E User Group #16 Radio Pendant Type - Default 0
P277E User Group #17 Radio Pendant Type - Default 0
P278E User Group #18 Radio Pendant Type - Default 0
P279E User Group #19 Radio Pendant Type - Default 0
P280E User Group #20 Radio Pendant Type - Default 0
Option 1 Generic Pendant Type - If this option is on then a Radio key loaded as a User has no specific type. In
this case, the code that is learnt must always be the same for it to work and it should not send any
special signals such as battery low.
Option 2 Freelink Pendant Type - This option identifies the Radio key as a Freelink type. When the Radio key
registers a low battery it is transmitted to the panel and recognised as such and reported at the keypad
and via the dialler if programmed to do so. The Freelink transmitters also include a special feature to
eliminate false triggers from other transmissions.
Option 3 Ness Pendant Type - This option identifies the Radio key as a Ness type. When the Radio key registers
a low battery it is transmitted to the panel and recognised as such and reported at the keypad and via
the dialler if programmed to do so.
USER GROUPS 1-20 OUTPUTS TO TURN ON P281E-P300E
This set of options allow a User code or radio key to control the turning ON of an Output directly. For this option to
work the options at in the corresponding group at addresses P201E-P220E must be OFF.
P281E User Group #1 Outputs 1-8 to turn On - Default 0
P282E User Group #2 Outputs 1-8 to turn On - Default 0
P283E User Group #3 Outputs 1-8 to turn On - Default 0
P284E User Group #4 Outputs 1-8 to turn On - Default 0
P285E User Group #5 Outputs 1-8 to turn On - Default 0
P286E User Group #6 Outputs 1-8 to turn On - Default 0
P287E User Group #7 Outputs 1-8 to turn On - Default 0
P288E User Group #8 Outputs 1-8 to turn On - Default 0
P289E User Group #9 Outputs 1-8 to turn On - Default 0
P290E User Group #10 Outputs 1-8 to turn On - Default 0
P291E User Group #11 Outputs 1-8 to turn On - Default 0
P292E User Group #12 Outputs 1-8 to turn On - Default 0
P293E User Group #13 Outputs 1-8 to turn On - Default 0
P294E User Group #14 Outputs 1-8 to turn On - Default 0
P295E User Group #15 Outputs 1-8 to turn On - Default 0
P296E User Group #16 Outputs 1-8 to turn On - Default 0