Page 38
P658E 1-8E Keypads with buzzer mapped to stay mode exit delay beeps (Default 1-8)
If the option is On, the keypad will sound the exit beeps when stay mode is armed to indicate the
exit delay has started.
P659E 1-8E Keypads with buzzer mapped to entry delay beeps (Default 1-8)
If the option is On, the keypad will sound the entry beeps to indicate the entry delay has started.
P660E 1-8E Keypad buzzer to warn of zone inactivity or supervised radio timeout alarm (Default 1-8)
If the option is On, a Supervised Radio signal failure or no activity on a zone for the
programmed period will cause the buzzer at the keypad to sound. Pressing any button
will silence the beep.
P661E 1-8E Keypads with buzzer mapped to keypad tampers (Default 1-8)
If the option is On, a keypad tamper alarm (four incorrect attempts to enter in a code) will cause
the buzzer at the keypad to sound.
P662E 1-8E Keypads with buzzer mapped to zone tampers (Default 1-8)
If the option is On, a zone tamper alarm will cause the buzzer at the keypad to sound.
P663E 1-8E Keypads with buzzer mapped to system tampers (Default 1-8)
If the option is On, a system tamper alarm or a remote LCD keypad tamper switch alarm will
cause the buzzer at the keypad to sound.
P664E 1-8E Keypads with buzzer mapped to Pendant “Panic” Alarm (Default 1-8)
If the option is On, a radio Pendant Panic alarm will cause the buzzer at the keypad to sound.
P665E 1-8E Keypads with buzzer mapped to keypad “Panic” Alarm (Default 1-8)
If the option is On, a Keypad Panic alarm will cause the buzzer at the keypad to sound.
P666E 1-8E Keypads with buzzer mapped to keypad “Fire” Alarm (Default 1-8)
If the option is On, a Keypad Fire alarm will cause the buzzer at the keypad to sound.
P667E 1-8E Keypads with buzzer mapped to keypad “Medical” Alarm (Default 1-8)
If the option is On, a Keypad Medical alarm will cause the buzzer at the keypad to sound.
P668E 1-8E Keypads with buzzer mapped to phone line failure (Default none)
If the option is On, a Telephone Line Failure will cause the buzzer at the keypad to sound..
Pressing any button will silence the beep.
P669E 1-8E Keypads with facility to turn the LED's off after Exit Delay (Default none)
If the option is On, the keypad LED’s, plus the LCD display & keypad backlighting on the
selected keypad/s will turn off when all areas assigned to the keypad are Armed or in Stay
mode. The LED’s and backlighting will automatically turn on again if there is an alarm, an entry
delay is started, any button is pressed at the keypad or when the system is Disarmed.
P670E 1-8E Keypad “A” button special arming options (Default 1)
The “A” button on the keypad can be assigned a single button arm function for any or all of the
four areas. To arm the alarm, the “A” button must be held down for 2 seconds. As well as
assigning an Area or areas to the button, it can also allow arming of the special Child disarm
reporting mode. If given this function, and the alarm is disarmed with a child code (see P221E-
P240E option 8), the panel will report the disarm to a selected telephone number/s.
P671E 1-8E Keypad “B” button special arming options (Default 2)
The “B” button on the keypad can be assigned a single button arm function for any or all of the
four areas. To arm the alarm, the “B” button must be held down for 2 seconds. As well as
assigning an Area or areas to the button, it can also allow arming of the special Child disarm
reporting mode. If given this function, and the alarm is disarmed with a child code (see P221E-
P240E option 8), the panel will report the disarm to a selected telephone number/s.
P670 & P761 SPECIAL ARMING OPTIONS
1 = Arms Area A 5 = Arms in “Child Disarm” report Mode
2 = Arms Area B 6 = Spare
3 = Arms Area C 7 = Spare
4 = Arms Area D 8 = Spare
PROGRAMMING DELAYS & TIMERS
OUTPUT RESET TIMES - P761E to P768E
This is the time the output will turn on for until it automatically resets again. A Zero means the output stays on until
the trigger is reset at the keypad.
P761E 0-999E Output #1 reset time - Default 600 seconds (10 min)
P762E 0-999E Output #2 reset time - Default 600 seconds (10 min)
P763E 0-999E Output #3 reset time - Default 600 seconds (10 min)
P764E 0-999E Output #4 reset time - Default 600 seconds (10 min)