Page 28
speech message via the panels internal speaker. With this option on the panel is expecting a
customised message to be programmed by the installer and the message numbers selected at
addresses P865E-P868E, if no message number is programmed, the panel will not play any local PA
message when Disarmed.
Option 2 Use Canned Local PA Disarm message. If option 1 above is on plus this option, the panel will play the
default “Canned” audio message when this Area is Disarmed provided no message is programmed at
addresses P865E-P868E.
Option 3 Repeat Local PA Disarm message. If option 1 or 2 or both are on above and this option is on, the
panel will repeat the local PA message when the Area is disarmed.
Option 4 Spare
Option 5 Enable Local PA Arm message. When the Area is Armed, it is possible to play a pre-recorded speech
message via the panels internal speaker. With this option on the panel is expecting a customised
message to be programmed by the installer and the message numbers selected at addresses P861E-
P864E, if no message number is programmed, the panel will not play any local PA message when
Armed.
Option 6 Use Canned Local PA Arm message. If option 5 above is on plus this option, the panel will play the
default “Canned” audio message when this Area is Armed provided no message is programmed at
addresses P861E-P864E.
Option 7 Repeat Local PA Arm message. If option 5 or 6 or both are on above and this option is on, the panel
will repeat the local PA message when the Area is Armed.
Note: P633E is the same as above but applies to Area B Local PA options
Note: P733E is the same as above but applies to Area C Local PA options
Note: P833E is the same as above but applies to Area D Local PA options
PARTITION "A" LOCAL PA STAY ARM MESSAGE OPTIONS - P534E
PARTITION "B" LOCAL PA STAY ARM MESSAGE OPTIONS - P634E
PARTITION "C" LOCAL PA STAY ARM MESSAGE OPTIONS - P734E
PARTITION "D" LOCAL PA STAY ARM MESSAGE OPTIONS - P834E
P534E 1E = Enable Local PA Area “A” Stay Armed message
2E = Use Canned Local PA Area “A” Stay Armed message
3E = Repeat Local PA Area “A” Stay Armed message
4E = Spare
5E = Spare
6E = Spare
7E = Spare
8E = Spare
Option 1 Enable Local PA Stay Armed message. When the Area is Armed in Stay mode, it is possible to play a
pre-recorded speech message via the panels internal speaker. With this option on the panel is expecting
a customised message to be programmed by the installer and the message numbers selected at
addresses P869E-P872E, if no message number is programmed, the panel will not play any local PA
message when Stay mode is armed.
Option 2 Use Canned Local PA Disarm message. If option 1 above is on plus this option, the panel will play the
default “Canned” audio message when this Area is Armed in Stay mode provided no message is
programmed at addresses P869E-P872E.
Option 3 Repeat Local PA Disarm message. If option 1 or 2 or both are on above and this option is on, the
panel will repeat the local PA message when the Area is Armed in Stay mode.
Note: P634E is the same as above but applies to Area B Local PA options
Note: P734E is the same as above but applies to Area C Local PA options
Note: P834E is the same as above but applies to Area D Local PA options