Page 27
AREA "A" TIME AND DELAY OPTIONS - P532E
AREA "B" TIME AND DELAY OPTIONS - P632E
AREA "C" TIME AND DELAY OPTIONS - P732E
AREA "D" TIME AND DELAY OPTIONS - P832E
P532E 1E = Arm area when time zone ends -Default off
2E = Disarm area when time zone starts - Default off
3E = Disable stay mode exit delay - Default off
4E = Disable arm mode exit delay - Default off
5E = Disable stay mode entry delay - Default off
6E = Disable arm mode entry delay - Default off
7E = Use special stay mode entry delay - Default off
8E = Report alarms and bypasses in stay mode via Dialler - Default off
Option 1 Arm area when time zone ends - this option will automatically arm area "A" when the time zone
programmed at address P529E finishes.
Option 2 Disarm area when the time zone starts - this option will automatically disarm area "A" when the
time zone programmed at address P529E starts.
Option 3 Disable stay mode exit delay - If this option is on the exit delay for area "A" becomes “0” when
arming stay mode (the delay will still apply to full arm unless option 4 is also on).
Option 4 Disable arm mode exit delay - If this option is on the exit delay for area "A" becomes “0” when
arming the panel (the delay will still apply to stay mode unless option 3 is also on).
Option 5 Disable stay mode entry delay - If this option is on then all zones are instant in stay mode
regardless of any entry delays programmed to zones (entry delays will still apply to zones in full
arm mode unless option 6 is also on).
Option 6 Disable arm mode entry delay - If this option is on then all zones are instant in full arm mode
regardless of any entry delays programmed to zones (entry delays will still apply to zones in stay
mode unless option 5 is also on).
Option 7 Use special stay mode entry delay - If this option is on then all Area A Stay mode zones use the
special Stay Mode entry delay (P845E) in stay mode and the normal delays programmed at
addresses P461E-P470E are ignored.
Option 8 Send alarms and bypasses in stay mode - If this option is on then all alarms and zone
bypasses in Stay mode will be reported via the dialler in Contact ID. Only zone alarms will be
reported if using Domestic/ Voice or Pager reporting formats. You should also note that if a Stay
mode alarm is not kissed off in Domestic/ Voice or Pager mode and the alarm is not disarmed,
when the dialler test time comes around, the zone alarms will report again. If this is not desired
you can stop this from happening by turning off all days for the test time at address P676E.
Note: P632E is the same as above but applies to Area B Time & Delay options
Note: P732E is the same as above but applies to Area C Time & Delay options
Note: P832E is the same as above but applies to Area D Time & Delay options
PARTITION "A" LOCAL PA ARM/DISARM MESSAGE OPTIONS - P533E
PARTITION "B" LOCAL PA ARM/DISARM MESSAGE OPTIONS - P633E
PARTITION "C" LOCAL PA ARM/DISARM MESSAGE OPTIONS - P733E
PARTITION "D" LOCAL PA ARM/DISARM MESSAGE OPTIONS - P833E
P533E 1E = Enable Local PA Area “A” Disarm message
2E = Use Canned Local PA Area “A” Disarm message
3E = Repeat Local PA Area “A” Disarm message
4E = Spare
5E = Enable Local PA Area “A” Arm message
6E = Use Canned Local PA Area “A” Arm message
7E = Repeat Local PA Area “A” Arm message
8E = Spare
Option 1 Enable Local PA Disarm message. When the Area is Disarmed, it is possible to play a pre-recorded