P497E Zone Group #7 Contact ID Tamper Code (Default = 137)
P498E Zone Group #8 Contact ID Tamper Code (Default = 137)
P499E Zone Group #9 Contact ID Tamper Code (Default = 137)
P500E Zone Group #10 Contact ID Tamper Code (Default = 137)
ZONE GROUP REPORTING ACCOUNT NUMBER
If a zone is in more than one Area, this address allows you to program which account code it will use when reporting
alarms.( 1 = Area A, 2 = Area B, 3 = Area C, 4 = Area D)
P501E Zone Group #1 Account # - Default 1
P502E Zone Group #2 Account # - Default 1
P503E Zone Group #3 Account # - Default 1
P504E Zone Group #4 Account # - Default 1
P505E Zone Group #5 Account # - Default 1
P506E Zone Group #6 Account # - Default 1
P507E Zone Group #7 Account # - Default 1
P508E Zone Group #8 Account # - Default 1
P509E Zone Group #9 Account # - Default 1
P510E Zone Group #10 Account # - Default 1
ZONE RESPONSE TIME FOR THE HARDWIRED ZONES 61-64.
P604E 1-31E. Default = 6
If there is a high level of noise introduced into the cables wired to the hardwired zones the time that the panel must
see a continuous alarm state before going into alarm can be adjusted at this address. Normally the default value of 6
is satisfactory but if required the time can be increased by programming a higher number at this address. The
maximum value allowed is a count of 31.
PROGRAMMING AREA “A,B,C & D” PARAMETERS
AREA "A" PRIMARY OUTPUT OPTIONS - P511E - P518E
AREA "B" PRIMARY OUTPUT OPTIONS - P611E - P618E
AREA "C" PRIMARY OUTPUT OPTIONS - P711E - P718E
AREA "D" PRIMARY OUTPUT OPTIONS - P811E - P818E
The addresses above allow a number Area based options to be assigned to any of the 8 outputs. Address P511
relates to Output 1 options for Area A, address P611 relates to Output 1 options for Area B, address P711 relates to
Output 1 options for Area C and address P811 relates to Output 1 options for Area D.
P511E 1E = Normal zone alarms to output #1
2E = Stay Mode alarms to output #1
3E = Pendant chirps to output #1
4E = All zones sealed indication to output #1
5E = 2 second pulse on arming or disarming to output #1
6E = Day zone alarms to output #1
7E = Spare
8E = Spare
Option 1 Normal zone alarms to output #1 - This option will map alarms from normal zone alarms from Area "A"
to output #1. Normal zones are those which will only activate when the area is armed.
Option 2 Stay Mode alarms to output #1 - This option will map alarms from zones defined as Area "A" Stay
Mode to output #1. Zones are defined as being in Stay Mode at addresses P411E-P420E option 5.
Option 3 Pendant Chirps to output #1 - This option will map two short pulses (Chirps) to output #1 when Area
"A" is armed via a radio key (Pendant) and four short pulses to output #1 when Area "A" is disarmed by
a radio key. The length of the pulses (Chirps) are set by the pulse timer for this output.
Option 4 All zones sealed indication to output #1 - This option will map an Area "A" “Ready” indication to
output #1. A “Ready” indication is produced when all zones in an area are sealed.