panel will repeat the local PA message when the Output turns ON.
Option 4 Spare
Option 5 Enable Local PA Output OFF message. When the Output is turned OFF, it is possible to play a pre-
recorded speech message via the panels internal speaker. With this option on the panel is expecting a
customised message to be programmed by the installer and the message numbers selected at
addresses P901E-P908E, if no message number is programmed, the panel will not play any local PA
message when the Output turns ON.
Option 6 Use Canned Local PA Arm message. If option 5 above is on plus this option, the panel will play the
default “Canned” audio message when the Output turns OFF provided there is no value set at
addresses P901E-P908E.
Option 7 Repeat Local PA Arm message. If option 5 or 6 or both are on above and this option is on, the panel
will repeat the local PA message when the Output turns OFF.
OUTPUT AUTO ON/OFF TIME ZONES - P581E - 588E
These addresses are used to map automatic ON and OFF periods to each of the outputs if required. When a time-
zone starts it will cause the output to turn on and when the time-zone ends it will cause the output to turn off. The
actual times assigned to each time-zone are defined at addresses P921E - P944E. Multiple Time Zones may be
assigned to each output.
P581E T/ZE Where T/Z represents a Time-Zone # from 1-8 which defines the turn on and turn off times
required for output #1
P582E T/ZE Where T/Z represents a Time-Zone # from 1-8 which defines the turn on and turn off times
required for output #2
P583E T/ZE Where T/Z represents a Time-Zone # from 1-8 which defines the turn on and turn off times
required for output #3
P584E - P588E As per above but for outputs 4-8
NOTE: A value of zero (0) at these addresses will disable any auto turn on turn off features at that output.
OUTPUT INHIBIT TIME ZONES - P591E - P598E
These addresses are used to map inhibit time-zones to each of the outputs as required. The assigned time-zone will
enable the output so that it can be used during the time-zone. If an output has a time-zone assigned and that time-
zone is off, the output cannot be turned on by any programmed function (the output is inhibited). The actual times
assigned to each time-zone are defined at addresses P921E - P944E. This feature can be used to allow the audible
alarms to only occur at pre-determined times and days.
P591E T/ZE Where T/Z represents the time zone which enables output #1
P592E T/ZE Where T/Z represents the time zone which enables output #2
P593E T/ZE Where T/Z represents the time zone which enables output #3
P594E - P598E As per above but for outputs 4-8
NOTE: A value of zero (0) at these addresses will enable that output at all times.
MISCELLANEOUS PANEL OPTIONS
MISCELLANEOUS PANEL OPTIONS - P601E
P601E 1E Ignore Mains input
2E Ignore zone tampers during exit delay
3E Installer has direct access to program mode
4E Installer lockout
5E Cabinet tamper is loop or end-of-line
6E Zones 61-64 use EOL resistor or short circuit loop
7E Low Key-switch is momentary or latching
8E High Key-switch is momentary or latching