Page 25
SPECIAL AREA ARM & STAY BUTTON OPTIONS FOR AREA A - P519E & P520E
SPECIAL AREA ARM & STAY BUTTON OPTIONS FOR AREA B - P619E & P620E
SPECIAL AREA ARM & STAY BUTTON OPTIONS FOR AREA C - P719E & P720E
SPECIAL AREA ARM & STAY BUTTON OPTIONS FOR AREA D - P819E & P820E
P519E "ARM" key can disarm Area “A” during exit delay - This option enables the one key disarm during
exit delay feature on a keypad by keypad basis for each area. Options 1-8 represent keypads 1-8.
P520E "STAY" key can disarm Area “A” during Stay Mode - This option enables single button disarm of
Stay mode via the "STAY" key. Options 1-8 represent keypads 1-8
Note: P619E & P620E are as above but apply to keypads in Area B
Note: P719E & P720E are as above but apply to keypads in Area C
Note: P819E & P820E are as above but apply to keypads in Area D
AREA "A" TIME ZONE AUTO ARM/DISARM OPTIONS - P529E
AREA "B" TIME ZONE AUTO ARM/DISARM OPTIONS - P629E
AREA "C" TIME ZONE AUTO ARM/DISARM OPTIONS - P729E
AREA "D" TIME ZONE AUTO ARM/DISARM OPTIONS - P829E
P529E 1-8 Time Zone to use for Auto Arm or Disarm of Area “A” (Default 0) - This option will determine
which Time Zone/s will cause Area "A" to arm, disarm or both, based on the programmed options
set at P532E for Area A.
Note: P629E is the same as above but applies to Area B Time Zone Arm/Disarm
Note: P729E is the same as above but applies to Area C Time Zone Arm/Disarm
Note: P829E is the same as above but applies to Area D Time Zone Arm/Disarm
PARTITION "A" MISCELLANEOUS KEYPAD OPTIONS - P530E
PARTITION "B" MISCELLANEOUS KEYPAD OPTIONS - P630E
PARTITION "C" MISCELLANEOUS KEYPAD OPTIONS - P730E
PARTITION "D" MISCELLANEOUS KEYPAD OPTIONS - P830E
P530E 1E = Cannot Arm if not Ready
2E = Arm key required before code to set
3E = Stay key required before code to arm Stay Mode
4E = Code required to arm area
5E = Code required to Bypass
6E = Control Button disables "Day/Chime" mode or directly Controls Outputs
7E = Repeat Current System alarm PA messages when Arming or Disarming
8E = Spare
Option 1 Cannot Arm if not Ready - This option if turned on will inhibit arming of Area “A” if any zone in area A
is unsealed (Not Ready). If the option is off, the area can be armed with zones unsealed but the panel
will either auto-bypass the zone or go into alarm at the end of the exit delay depending upon other option
settings. If required, certain zones can be exempted from this feature if they are in low security areas,
allowing the area to be armed with a zone/s unsealed, by programming the zone group option at
addresses P421E-P430E option 7. This option does not apply to Stay mode.
Option 2 Arm key required before code to arm - This option determines if the "ARM" key must be pressed
before a code is entered to arm Area "A". This option should be enabled where the keypad is assigned
to more than one area.
Option 3 Stay key required before code to arm Stay Mode - This option determines if the "STAY" key is a
single button function or must be pressed followed by a code to turn on Stay Mode in Area "A". This
option should be enabled where the keypad is assigned to more than one area. If off, Stay mode is
turned on by pressing the Stay button only, if on, you must enter a code after pressing the stay button.
When Arming Stay Mode, if the user presses the “Enter” button during the exit delay, this will cancel any
remaining exit delay time and make all Stay zones instant, even if they have an entry delay time
programmed.
Option 4 Code required to arm area - If this option is off the area can be armed with a single press of the arm