Page 33
control outputs with this option turned on, the user must press the “Control” button on the keypad for 2
seconds. The display will read “ OUTPUTS”. Any outputs that are currently on will have their number
shown on the LCD display. To turn outputs On or Off simply press the number that corresponds to the
output you wish to control. The output number on the display will follow the output state e.g. if the
output is on, the corresponding number will be on, if off, no number will be displayed.
Option 7 Day Zones Linked to Pulse Timer - Day Zones programmed to operate this output will pulse the
output at the rate programmed for the pulse timer (e.g. if it is output #1 then the timer at P781E
applies).
Option 8 Pulsed 24 hour alarm - If a 24 hour zone activates the alarm this option will cause the output to pulse
at a rate equal to the value set for the pulse timer for this output. This feature is provided to
differentiate between a burglar and fire alarm using the same siren.
P542E - P548E As per P541E above for Outputs 2-8
ALARMS TO OUTPUT OPTIONS - P551E - P558E
In this block of addresses P551E relates to output #1, P552E relates to output #2 etc
P551E 1E = Keypad Panic Alarm to Output #1
2E = Keypad Fire Alarm to Output #1
3E = Keypad Medical Alarm to Output #1
4E = Duress Alarm to Output #1
5E = Wrong Code Tamper Alarm to Output #1
6E = Radio Key Panic Alarm to Output #1
7E = 24 Hour Zone Alarm to Output #1
8E = 24 Hour Fire Zone Alarm to Output #1
Option 1 Keypad Panic to Output - This option is used to map the operation of the keypad panic to an output
i.e. when the “Chime” & “Control” buttons on the keypad are pressed simultaneously any output with
this option enabled will turn on.
Option 2 Keypad Fire Alarm to Output - This option is used to map the operation of the keypad Fire Alarm to
an output i.e. when the “A” & “B” buttons on a keypad are pressed simultaneously any output with this
option enabled will turn on.
Option 3 Keypad Medical Alarm to Output - This option is used to map the operation of the keypad Medical
Alarm to an output i.e. when the “B” & “Chime” buttons on a keypad are pressed simultaneously any
output with this option enabled will turn on.
Option 4 Duress Alarm to Output - This option is used to map a Duress Alarm to an output. A Duress Alarm
is generated when the alarm is unset by a valid user that adds the duress digit to the beginning of their
code.
Option 5 Wrong Code Tamper Alarm to Output - This option is used to map the Wrong Code Tamper Alarm
to an output. A Wrong Code Tamper Alarm is generated if an invalid code is entered more than 4 times
at a keypad. This option will cause the output to turn on when this alarm condition is present.
Option 6 Radio Key Panic Alarm to Output - This option is used to map the operation of the Radio Key Panic
Alarm to an output i.e. when the Radio Panic is generated any output with this option enabled will turn
on.
Option 7 24 Hour Zone Alarm to Output - This option is used to map 24 Hour Zone Alarms to an output i.e.
when the 24 Hour Zone Alarm is generated any output with this option enabled will turn on.
Option 8 24 Hour Fire Zone Alarm to Output - This option is used to map 24 Hour Fire Alarms to an output.
When the 24 Hour Fire Alarm is generated this will cause the output to flash at a rate set by the pulse
timer for this output to identify the difference between a fire alarm and normal burglar alarm.