P765E 0-999E Output #5 reset time - Default 0 (latching)
P766E 0-999E Output #6 reset time - Default 0 (latching)
P767E 0-999E Output #7 reset time - Default 0 (latching)
P768E 0-999E Output #8 reset time - Default 0 (latching)
MAINS FAIL REPORTING DELAY TIME - P769E
The Mains voltage (AC input) must fail for longer than this time before it will report via the dialler or play the local PA
message.
P769E 0-999E Mains Fail Dialler Report Delay - Default 600 seconds
ZONE ALARM REPORT DELAY TIME - P770E
When the panel is armed and a zone alarm occurs, if there is a value programmed at this address the reporting of
the alarm signal via the dialler will be aborted for this period of time. If the alarm is disarmed before this time
expires, no alarm will be sent.
P770E 0-999E Zone Alarm Report Delay to Dialler - Default 0 seconds
OUTPUT DELAY ON TIMES - P771E to P778E
If the output is turned on for some reason and a value is programmed at this address, the turning on of the output
will be delayed by this time.
P771E 0-999E Output #1 delay on timer - Default 0 (instant)
P772E 0-999E Output #2 delay on timer - Default 0 (instant)
P773E 0-999E Output #3 delay on timer - Default 0 (instant)
P774E 0-999E Output #4 delay on timer - Default 0 (instant)
P775E 0-999E Output #5 delay on timer - Default 0 (instant)
P776E 0-999E Output #6 delay on timer - Default 0 (instant)
P777E 0-999E Output #7 delay on timer - Default 0 (instant)
P778E 0-999E Output #8 delay on timer - Default 0 (instant)
ZONE INACTIVITY DELAY TIME - P779E
If a zone group has the “Zone Inactivity” option turned on, this is the time period for the inactivity timeout. Every time
a zone triggers at the panel, the Inactivity timer for the zone is reset back to zero. If the time period expires, a zone
inactivity alarm will be generated. The timer is stopped and the value saved when the area assigned to the zone
group is armed. When the area is disarmed the timer continues from the saved value.
P779E 0-999E Zone Inactivity Timer (0-999 hours) - Default 120 hours
SUPERVISED RADIO SIGNAL TIME - P780E
If a wireless detector type that has a supervised signal is set for a particular zone group the panel will be monitoring
all supervised zones for the supervisory transmission. Every time a supervised signal is received from a detector
the supervisory timer for that detector will be reset. If the timer expires due to no transmissions from a detector, the
panel will generate a supervised failure for that detector.
P780E 0-999E Supervised Radio Timer (0-999 minutes) - Default 240 minutes
OUTPUT PULSE TIMES - P781E to P788E
The pulse timer is a time set in 1/10 second intervals that can pulse the output at a fast rate.
P781E 0-999E Output #1 pulse time -Default 0 (0 = Minimum 0.1 sec pulse) Times are in 1/10 second
P782E 0-999E Output #2 pulse time -Default 0 (0 = Minimum 0.1 sec pulse) increments
P783E 0-999E Output #3 pulse time -Default 0 (0 = Minimum 0.1 sec pulse)
P784E 0-999E Output #4 pulse time -Default 0 (0 = Minimum 0.1 sec pulse)
P785E 0-999E Output #5 pulse time -Default 0 (0 = Minimum 0.1 sec pulse)
P786E 0-999E Output #6 pulse time -Default 0 (0 = Minimum 0.1 sec pulse)
P787E 0-999E Output #7 pulse time -Default 0 (0 = Minimum 0.1 sec pulse)