Page 22
ZONE GROUP ENTRY DELAY TIME
This is the entry delay time all zones assigned with this group number will use when armed. If the alarm is disarmed
before the delay expires then no alarm will be generated. The delay also applies to 24 hour zones. A zero means
there is no entry delay. The range allowed is 0-9999 seconds.
P461E Zone Group #1 Entry Delay - Default 20
P462E Zone Group #2 Entry Delay - Default 0
P463E Zone Group #3 Entry Delay - Default 0
P464E Zone Group #4 Entry Delay - Default 0
P465E Zone Group #5 Entry Delay - Default 0
P466E Zone Group #6 Entry Delay - Default 0
P467E Zone Group #7 Entry Delay - Default 0
P468E Zone Group #8 Entry Delay - Default 0
P469E Zone Group #9 Entry Delay - Default 0
P470E Zone Group #10 Entry Delay - Default 0
ZONE GROUP DIALLING SCENARIO NUMBER
There are four dialling scenarios that can be programmed allowing the option of having different zones report to
different monitoring stations. Alternatively, you could have some zones report to a monitoring station and some plant
alarms report using voice messages to a technicians mobile telephone.
P471E Zone Group #1 Scenario # - Default 1
P472E Zone Group #2 Scenario # - Default 1
P473E Zone Group #3 Scenario # - Default 1
P474E Zone Group #4 Scenario # - Default 1
P475E Zone Group #5 Scenario # - Default 1
P476E Zone Group #6 Scenario # - Default 1
P477E Zone Group #7 Scenario # - Default 1
P478E Zone Group #8 Scenario # - Default 1
P479E Zone Group #9 Scenario # - Default 1
P480E Zone Group #10 Scenario # - Default 1
ZONE GROUP ALARM CONTACT ID REPORTING CODE
When a zone group reports an alarm to a monitoring station using Contact ID, the default event type is a code 130 for
“Burglar Alarm”. Should you require some zone groups to report alarms as Fire or Medical alarms, etc, you can
change the event code transmitted using these addresses.
P481E Zone Group #1 Contact ID Alarm Code (Default = 130)
P482E Zone Group #2 Contact ID Alarm Code (Default = 130)
P483E Zone Group #3 Contact ID Alarm Code (Default = 130)
P484E Zone Group #4 Contact ID Alarm Code (Default = 130)
P485E Zone Group #5 Contact ID Alarm Code (Default = 130)
P486E Zone Group #6 Contact ID Alarm Code (Default = 130)
P487E Zone Group #7 Contact ID Alarm Code (Default = 130)
P488E Zone Group #8 Contact ID Alarm Code (Default = 130)
P489E Zone Group #9 Contact ID Alarm Code (Default = 130)
P490E Zone Group #10 Contact ID Alarm Code (Default = 130)
ZONE GROUP CONTACT ID TAMPER REPORTING CODE
When a zone tamper reports an alarm to a monitoring station using Contact ID, the default event type is a code 137
for “Tamper”. Should you require some zone group tampers to report a different code, you can change the event
code transmitted using these addresses.
P491E Zone Group #1 Contact ID Tamper Code (Default = 137)
P492E Zone Group #2 Contact ID Tamper Code (Default = 137)
P493E Zone Group #3 Contact ID Tamper Code (Default = 137)
P494E Zone Group #4 Contact ID Tamper Code (Default = 137)
P495E Zone Group #5 Contact ID Tamper Code (Default = 137)
P496E Zone Group #6 Contact ID Tamper Code (Default = 137)