PW64 CONTACT ID CODE SUMMARY
In addition to the programmable Contact ID Event Code assignments defined at P747E - P749E and P481E-
P500E there are a number of fixed event codes. The programmable and fixed event codes are all listed in the
table below. Associated with the fixed and programmable event codes, there are a number of extension codes,
that are also listed below. This extensions list is for your reference only and can not be changed in programming.
Event Code Extension Comment
Cabinet Tamper 137 000 Panel Tamper
Radio Zone Tamper 137 001 to 060 Zones 1-60
Zone Tamper - Input 61 (open circuit) 137 062 Hardwired Zone Tamper on I/P 61
Zone Tamper - Input 62 (open circuit) 137 064 Hardwired Zone Tamper on I/P 62
Zone Tamper - Input 61 (short circuit) 137 061 Hardwired Zone Tamper on I/P 61
Zone Tamper - Input 62 (short circuit) 137 062 Hardwired Zone Tamper on I/P 62
**Keypad Tamper (Wrong Code) 137 101 At keypad #1
through to 108 At keypad #8
**Keypad Panic 120 001 At keypad #1
through to 008 At keypad #8
**Keypad Medical 100 001 At keypad #1
through to 008 At keypad #8
**Keypad Fire 110 001 At keypad #1
through to 008 At keypad #8
**Duress Alarm 121 001 At keypad #1
through to 008 At keypad #8
Arm by "ARM key (shortcut) 408 000 User number zero
Arm by user code 401 001 User #1
through to 100 User #100
Arm by Radio-key 407 021 Radio User #21
through to 100 Radio User #100
Arm by Time Zone 403 000 Time Zone arming
Arm by Key-switch 409 001 Key-switch Arm/Disarm KS#1
Arm by Key-switch 409 002 Key-switch Arm/Disarm KS#2
Arm by Up/Download 400 000
Arm by DTMF remote control 400 000
Radio-key Panic 120 121 Radio User #21
through to 200 Radio User #100
Radio PIR / Reed Switch Activation 130 001 Zone 1
(& Hardwired zones 61-64) through to 064 Zone 64
System Battery Low 302 000 Control Panel Battery low
Mains Fail 301 000 230v mains to control panel lost
12V Supply Fail 312 000 12V Fuse F1 or F2 blown
Radio PIR / Reed Switch Battery Low 384 001 Zone 1
through to 060 Zone 60
Radio-key Battery Low 384 121 Radio-key #21
through to 200 Radio-key #100
Radio Zone Supervised Failure 381 001 Radio Zone #1
through to 060 Radio Zone #60
Zone Inactivity Alarm 391 001 Zone #1
through to 060 Zone #60
TEST Calls 602 000 24 hour test
Zone Bypasses 570 001 Bypass Zone 1
through to 064 Bypass Zone 64
Phone Line Failure 351 000 Reported when line is restored
Stay Mode (part set) 441 000 Arm by “Stay” Button
001 User 1
through to 100 User 100
Stay Mode by Key-switch (part set) 442 001 “Stay” mode Arm by K/S #1
002 “Stay” mode Arm by K/S #2
** - Note: On some versions of the panel the keypad number is not sent (ie Extension =“000”) to satisfy some