PROGRAMMING TEST CALL OPTIONS - P676E - P677E
Because the PW64 runs a real time clock, it is possible to assign test calls by day of the week and time of day.
P676E 0-7E Test Call Days of the Week - Where 1 = Sunday and 7 = Saturday. 0 = No Test
P677E XXXXE Test Call Time of Day - Where the time of the day you wish the panel to make its daily test
call is programmed in 24 hour format.
CONTACT ID CODE & SPEECH MESSAGE PROGRAMMING
CONTACT ID AREA ACCOUNT CODES - P536E ,P636E,P736E & P836E
P536E XXXXE Account Code for Area "A" Reports - The Account code set at this address will be used to
report all system events Arms and Disarms, zone activations, restores and bypasses etc from
Area "A" - Default Account = 0000
P636E XXXXE Account Code for Area "B" Reports - The account code set at this address will be used to
report Arms and Disarms, zone activations, restores and bypasses etc from Area "B"
P736E XXXXE Account Code for Area "C" Reports - The account code set at this address will be used to
report Arms and Disarms, zone activations, restores and bypasses etc from Area "C"
P836E XXXXE Account Code for Area "D" Reports - The account code set at this address will be used to
report Arms and Disarms, zone activations, restores and bypasses etc from Area "D"
ZONE GROUP CONTACT ID ALARM REPORTING CODE - P481E-P490E
This is the Contact ID event code that the zone group will send when an alarm occurs on a zone assigned to that
group. The default setting of “130” means a burglar alarm. If you have panic alarms, fire alarms or some other alarm
type on specific groups you can re-program this code to identify the type of alarm correctly.
P481E XXXE Zone Group #1 Alarm reporting code Default = 130 0 = No Report
P482E XXXE Zone Group #2 Alarm reporting code Default = 130
P483E XXXE Zone Group #3 Alarm reporting code Default = 130
P484E XXXE Zone Group #4 Alarm reporting code Default = 130
P485E XXXE Zone Group #5 Alarm reporting code Default = 130
P486E XXXE Zone Group #6 Alarm reporting code Default = 130
P487E XXXE Zone Group #7 Alarm reporting code Default = 130
P488E XXXE Zone Group #8 Alarm reporting code Default = 130
P489E XXXE Zone Group #9 Alarm reporting code Default = 130
P490E XXXE Zone Group #10 Alarm reporting code Default = 130
ZONE TAMPER ALARM CONTACT ID REPORTING CODES - P491E-P500E
This is the Contact ID event code that the zone group will send when a tamper alarm occurs on a zone assigned to
that group. The default setting of “137” means a tamper alarm. If you wish to identify this alarm as some other alarm
type on specific groups you can re-program this code to identify the type of alarm correctly.
P491E XXXE Zone Group #1 Tamper Alarm reporting code Default = 137 0 = No Report
P492E XXXE Zone Group #2 Tamper Alarm reporting code Default = 137
P493E XXXE Zone Group #3 Tamper Alarm reporting code Default = 137
P494E XXXE Zone Group #4 Tamper Alarm reporting code Default = 137
P495E XXXE Zone Group #5 Tamper Alarm reporting code Default = 137
P496E XXXE Zone Group #6 Tamper Alarm reporting code Default = 137
P497E XXXE Zone Group #7 Tamper Alarm reporting code Default = 137
P498E XXXE Zone Group #8 Tamper Alarm reporting code Default = 137
P499E XXXE Zone Group #9 Tamper Alarm reporting code Default = 137
P500E XXXE Zone Group #10 Tamper Alarm reporting code Default = 137