MANUAL ALARM CONTACT ID REPORTING CODES - P747E-P749E
This is the Contact ID event code that the Manually generated Keypad alarms will send when a triggered by a User. If
you wish to identify these alarms differently you can re-program the codes at the addresses below.
P747E XXXE “Panic” Keypad Alarm Default = 120
P748E XXXE “Fire” Keypad Alarm Default = 110
P749E XXXE “Medical” Keypad Alarm Default = 100
ZONE GROUP ALARM VOICE MESSAGE MAPPING - P451E - P460E
These addresses are used to assign the customised voice messages to the zone group alarms. The voice messages
will be played over the phone in response to an alarm activation to those phone numbers which have been assigned
Speech Dial format at options P697E to P702E. If the setting is left at “0”, the panel will play the canned message.
P451E 0-47E Customised Voice Message Mapped to Zone Group # 1 Activation's - Default 0
P452E 0-47E Customised Voice Message Mapped to Zone Group # 2 Activation's - Default 0
P453E 0-47E Customised Voice Message Mapped to Zone Group # 3 Activation's - Default 0
P454E 0-47E Customised Voice Message Mapped to Zone Group # 4 Activation's - Default 0
P455E 0-47E Customised Voice Message Mapped to Zone Group # 5 Activation's - Default 0
P456E 0-47E Customised Voice Message Mapped to Zone Group # 6 Activation's - Default 0
P457E 0-47E Customised Voice Message Mapped to Zone Group # 7 Activation's - Default 0
P458E 0-47E Customised Voice Message Mapped to Zone Group # 8 Activation's - Default 0
P459E 0-47E Customised Voice Message Mapped to Zone Group # 9 Activation's - Default 0
P460E 0-47E Customised Voice Message Mapped to Zone Group # 10 Activation's - Default 0
MISCELLANEOUS ALARMS, VOICE MESSAGE MAPPING - P881E - P889E
These addresses are used to assign the customised voice messages to the manually generated Panic,/Fire,/Medical
alarms, battery low and mains failure, Radio Battery low, Supervisory Alarm and tamper alarm messages. The voice
messages will be played over the phone in response to an alarm activation to those phone numbers which have been
assigned Speech Dial format at options P697E to P702E. If the setting is left at “0”, the panel will play the canned
message.
P881E 0-47E Voice Message Mapped to Pendant “Panic” Alarm - Default 0
P882E 0-47E Voice Message Mapped to Keypad “Panic” Alarm - Default 0
P883E 0-47E Voice Message Mapped to Keypad “Fire” Alarm - Default 0
P884E 0-47E Voice Message Mapped to Keypad “Medical” Alarm - Default 0
P885E 0-47E Voice Message Mapped to Battery Low Alarm - Default 0
P886E 0-47E Voice Message Mapped to Mains Failure Alarm - Default 0
P887E 0-47E Voice Message Mapped to Radio Device Low battery - Default 0
P888E 0-47E Voice Message Mapped to Radio Supervisory Failure Alarm - Default 0
P889E 0-47E Voice Message Mapped to Zone or System Tamper Alarm - Default 0
MISCELLANEOUS DIALLER OPTIONS
KEYPAD LISTEN-IN OPTIONS
The buzzer on the LCD keypad can be used to listen to the dialler during various On-line states. If this option is not
wanted you must turn off all of the options at this address. It is a very useful tool for testing the dialler on a new
installation when sending signals to monitoring stations or calls to cell-phones, etc as the installer can hear the call
being made to verify correct operation.
P606E Keypad Listen-in Options (Default = 1,7)
1 = Enabled During Dialling in Disarm State only
2 = Enabled During Dialling in Armed State only
3 = Enabled During Dialling in Monitor Mode State only
4 = Enabled Throughout the call in Disarm State only
5 = Enabled Throughout the call in Armed State only
6 = Enabled Throughout the call in Monitor Mode State only
7 = Listen-in Enabled when the panel answers a call