Page 29
AREA “A” DIALLER REPORTING OPTIONS - P535E
AREA “B” DIALLER REPORTING OPTIONS - P635E
AREA “C” DIALLER REPORTING OPTIONS - P735E
AREA “D” DIALLER REPORTING OPTIONS - P835E
P535E 1-8E Area A Reporting Options - Default 1,2
1 = Send Arm/Disarm
2 = Send Stay Mode Arm/Disarm
3 = Send Disarm only after activations
4 = Send Stay Disarm only after activations
5 = Send Arm at the end of the exit delay
6 = Send all zone restores when disarmed
7 = Spare
8 = Spare
Option 1 Send Arm / Disarm - If this option is on, the dialler will report Area "A" arms and disarms.
Option 2 Send Stay Mode Arm / Disarm - If this option is on, the dialler will report Area "A" stay mode
arms and disarms.
Option 3 Send Disarm only after activation - If this option is on, the dialler will report an Area A disarm
following an alarm activation only. This option is often used in conjunction with alarm only
reporting and stops the normal arm/disarm signals from being sent. If this option is on it will
override the option 1 setting.
Option 4 Send Stay Mode Disarm only after activation - If this option is on, the dialler will report an Area
A Stay Mode disarm following an alarm activation only. This option is often used in conjunction
with alarm only reporting and stops the normal Stay Mode arm/disarm signals from being sent. If
this option is on it will override the option 2 setting.
Option 5 Send Arm at the end of the exit delay - If this option is Off, the dialler will report an Arm
immediately the panel is armed. If the option is On, the Arm report is sent at the expiry of the exit
delay.
Option 6 Send all zone restores when disarmed - If this option is off, the dialler will send all zone
restores as they occur. If the option is on, the dialler will send all zone restores only when the
panel is disarmed. If the option is On, only one restore will be sent for each zone that activates
regardless of whether the zones can send multiple alarm reports.
P635E 1-8E Area "B" Reporting Options - (see above for details) Default 1,2
P735E 1-8E Area "C" Reporting Options - (see above for details) Default 1,2
P835E 1-8E Area "D" Reporting Options - (see above for details) Default 1,2
AREA “A” DIALLER REPORTING ACCOUNT NUMBER - P536E
AREA “B” DIALLER REPORTING ACCOUNT NUMBER - P636E
AREA “C” DIALLER REPORTING ACCOUNT NUMBER - P736E
AREA “D” DIALLER REPORTING ACCOUNT NUMBER - P836E
The account number is a four digit number that is sent every time the dialler reports alarms in Contact ID or 4+2
mode. The account code is also included in the Pager transmission. The special characters of B,C,D,E & F can be
programmed as any of the 4 digits of the account code (see chart on page 54 for details).
AREA “A” ARM/DISARM REPORTING SCENARIO NUMBER - P537E
AREA “B” ARM/DISARM REPORTING SCENARIO NUMBER - P637E
AREA “C” ARM/DISARM REPORTING SCENARIO NUMBER - P737E
AREA “D” ARM/DISARM REPORTING SCENARIO NUMBER - P837E
The Arm/Disarm Scenario number is the telephone number or numbers that the panel will report to when sending the
Arm & Disarm signals for each Area.