Page 40
P788E 0-999E Output #8 pulse time -Default 0 (0 = Minimum 0.1 sec pulse)
AREA EXIT DELAY TIMES - P841E to P5844E
This is the delay time applicable to all zones in an area following arming before the system is fully armed.
P841E 0-999E Area "A" exit delay - 0-999 seconds - Default 60 seconds
P842E 0-999E Area "B" exit delay - 0-999 seconds - Default 60 seconds
P843E 0-999E Area "C" exit delay - 0-999 seconds - Default 60 seconds
P844E 0-999E Area "D" exit delay - 0-999 seconds - Default 60 seconds
STAY MODE ENTRY DELAY TIMES - P845E to P848E
This is the delay time applicable to all Stay Mode zones in an area following an alarm trigger before the alarm
occurs..
P845E 0-999E Area "A" Special Stay Mode entry delay - Default 20 seconds
P846E 0-999E Area "B" Special Stay Mode entry delay - Default 20 seconds
P847E 0-999E Area "C" Special Stay Mode entry delay - Default 20 seconds
P848E 0-999E Area "D" Special Stay Mode entry delay - Default 20 seconds
TWO TRIGGER TIMER - P849E
If a zone or zones are set to two trigger, they must activate twice within the two trigger period to cause an alarm. A
single zone can trigger twice or two separate zones trigger once each within this time to create an alarm. If only one
trigger is received before the two trigger timer expires, the timer is reset and the process must be repeated. Also, if a
two trigger zone is left continuously un-sealed longer than the two trigger time an alarm will be generated.
P849E 0-999E Two Trigger time period - Default 60 seconds
DAY ZONE TO KEYPAD BUZZER TIMES - P851E to P854E
If a Day alarm is generated, this time will set how long the keypad buzzer will sound before resetting.
P851E 1-999E Area "A" Day Zone keypad buzzer duration - Default 2 seconds
P852E 1-999E Area "B" Day Zone keypad buzzer duration - Default 2 seconds
P853E 1-999E Area "C" Day Zone keypad buzzer duration - Default 2 seconds
P854E 1-999E Area "D" Day Zone keypad buzzer duration - Default 2 seconds
DAY ZONE TO OUTPUT TIMES - P855E to P858E
If a Day alarm is generated, this time will set how long an output will turn on before resetting.
P855E 1-999E Area "A" Day Zone to Output duration - Default 2 seconds
P856E 1-999E Area "B" Day Zone to Output duration - Default 2 seconds
P857E 1-999E Area "C" Day Zone to Output duration - Default 2 seconds
P858E 1-999E Area "D" Day Zone to Output duration - Default 2 seconds
PROGRAMMING REAL TIME CLOCK AND TIME ZONES
SETTING THE REAL TIME CLOCK - P678E - P682E
These addresses are used to set the internal real time clock used by the time zone functions, time & date stamping of
events in the event buffer and the time for any automatic test calls to a monitoring station.
P678E 1-7E Set day of the week - where values of 1-7 represent Sunday to Saturday (Sunday = 1)
P679E 0000 - 2359E Set time - Use 24 hour format
P680E 1-31E Set day of the month - where values of 1-31 represent days in the month.
P681E 1-12E Set Month - where values of 1-12 represent the month.
P682E 0-99 Set Year - Where 0-99 represent years, i.e. 02 = 2002.