Page 63
P419E Zone Group #9 Options A Default 1,6,7
P420E Zone Group #10 Options A Default 1,6,7
Zone Group Options B Zone Options B
P421E Zone Group #1 Options B Default 0 1 = Is a 24 Hour Zone Page 19
P422E Zone Group #2 Options B Default 0 2 = Is a 24 Hour Fire Zone
P423E Zone Group #3 Options B Default 0 3 = Is a 24 Hour Auto-Reset Zone
P424E Zone Group #4 Options B Default 0 4 = Is a Permanent Day Zone
P425E Zone Group #5 Options B Default 0 5 = Is a Handover Zone
P426E Zone Group #6 Options B Default 0 6 = Is a two Trigger Zone
P427E Zone Group #7 Options B Default 0 7 = Can Arm if zone not “Ready”
P428E Zone Group #8 Options B Default 0 8 = Is a Siren Lockout Zone
P429E Zone Group #9 Options B Default 0
P430E Zone Group #10 Options B Default 0
Zone Group Options C Zone Options C
P431E Zone Group #1 Options C Default 1 1 = Send Multiple reports via dialler Page 20
P432E Zone Group #2 Options C Default 1 2 = Zone is monitored for Inactivity
P433E Zone Group #3 Options C Default 1 3 = Zone is in Soak-test Mode
P434E Zone Group #4 Options C Default 1 4 = Zone is NC or NO.
P435E Zone Group #5 Options C Default 1 5 = Enable Zone Group PA Alarm msg
P436E Zone Group #6 Options C Default 1 6 = Use Canned Zone Group PA Alarm msg
P437E Zone Group #7 Options C Default 1 7 = Repeat Zone Group PA Alarm msg
P438E Zone Group #8 Options C Default 1 8 = Spare
P439E Zone Group #9 Options C Default 1
P440E Zone Group #10 Options C Default 1
Zone Group Radio sensor Mode Zone Radio Mode
P441E Zone Group #1 Radio Mode - Default 0 1 = Crow AE Battery Low Page 21
P442E Zone Group #2 Radio Mode - Default 0 2 = Crow AE reed Switch
P443E Zone Group #3 Radio Mode - Default 0 3 = Crow Merlin - Supervised signal ignored
P444E Zone Group #4 Radio Mode - Default 0 4 = Crow Merlin - Supervised signal active
P445E Zone Group #5 Radio Mode - Default 0 5 = Freelink Protocol with Checksum - Supervised
P446E Zone Group #6 Radio Mode - Default 0 6 = Freelink Protocol with Checksum - Non-supervised
P447E Zone Group #7 Radio Mode - Default 0 11 = Ness battery low
P448E Zone Group #8 Radio Mode - Default 0 12 = Ness Reed Switch
P449E Zone Group #9 Radio Mode - Default 0 21 = Electronics Line Cougar PIR
P450E Zone Group #10 Radio Mode - Default 0 31 = Visonic K980W PIR
Zone Group Voice Message # Zone Voice Alarm/PA Message Number Page 21
P451E Zone Group #1 Voice Msg # - Default 0 This is the voice message all zones assigned to this group
P452E Zone Group #2 Voice Msg # -Default 0 number will send when an alarm occurs on the zone. The
P453E Zone Group #3 Voice Msg # - Default 0 message is used for both alarm reporting and local PA.
P454E Zone Group #4 Voice Msg # - Default 0
P455E Zone Group #5 Voice Msg # - Default 0 (If no message is assigned at this address the default “Canned”
P456E Zone Group #6 Voice Msg # - Default 0 message will be played, see also P431-P440)
P457E Zone Group #7 Voice Msg # - Default 0
P458E Zone Group #8 Voice Msg # - Default 0
P459E Zone Group #9 Voice Msg # - Default 0
P460E Zone Group #10 Voice Msg # - Default 0
Zone Group Entry Delay Time Zone Entry Delay Time Page 22
P461E Zone Group #1 Entry Delay - Default 20 This is the entry delay time all zones assigned with this group
P462E Zone Group #2 Entry Delay - Default 0 number will use when armed. A zero here means the zone is
P463E Zone Group #3 Entry Delay - Default 0 instant. A value from 0-9999 seconds can be entered.
P464E Zone Group #4 Entry Delay - Default 0
P465E Zone Group #5 Entry Delay - Default 0
P466E Zone Group #6 Entry Delay - Default 0
P467E Zone Group #7 Entry Delay - Default 0
P468E Zone Group #8 Entry Delay - Default 0
P469E Zone Group #9 Entry Delay - Default 0
P470E Zone Group #10 Entry Delay - Default 0
Zone Group Dialling Scenario # Zone Dialling Scenario Number