Notch Alignment: 0*, 1 0 = Disabled
1 = Enabled
Notch Threshold: 0, 1*, 2, 3, 4, 5, 6 0 = 30 %
1 = 40 %
2 = 50 %
3 = 60 %
4 = 70 %
5 = 80 %
6 = 90 %
Notch Distance [mm]
PaperEnd Buffer Clear: 0*, 1 0 = Disabled
1 = Enabled
Short ticket (<150mm): 0*, 1 0 = Disabled
1 = Enabled
Print Density: 0, 1, 2, 3, 4*, 5, 6, 7, 8 0 = - 50 %
1 = - 37 %
2 = - 25 %
3 = - 12 %
4 = 0 %
5 = + 12 %
6 = + 25 %
7 = + 37 %
8 = + 50 %
[INTERFACE]
RS232 Baud Rate: 1, 2, 3, 4, 5, 6, 7, 8* 1 = 1200 bps
2 = 2400 bps
3 = 4800 bps
4 = 9600 bps
5 = 19200 bps
6 = 38400 bps
7 = 57600 bps
8 = 115200 bps
RS232 Data Length: 0*, 1 0 = 8 bits/chr
1 = 7 bits/chr
RS232 Parity: 0*, 1, 2 0 = None
1 = Even
2 = Odd
RS232 Handshaking: 0*, 1 0 = Xon/Xoff
1 = Hardware
Busy Condition: 0*, 1 0 = RxFull
1 = OffLine/RxFull
USB Mass Storage: 0*, 1 0 = Disabled
1 = Enabled
USB Address Number: 0*, 1, 2, 3, 4, 5, 6, 7, 8, 9 0 = 0
1 = 1
2 = 2
3 = 3
4 = 4
5 = 5
6 = 6
7 = 7
8 = 8
9 = 9
[SVELTA]
Ticket X Dimension
Ticket Y Dimension
Notch Distance
Notch Width
Barcode Timeout
Ticket Offset X
Ticket Offset Y
[NETWORK]
DHCP Client: 0*, 1 0 = Disabled
1 = Enabled
12. ADVANCED FUNCTIONS