51
Table 7-6 Areas outputs programming
Submenu Setting
TYPE
AREA ON
: Follows area(s) armed status.
AREA OFF
: Follows area(s) armed status.
PART1 ON
: Follows partition 1 armed status.
PART2 ON
: Follows partition 2 armed status.
EXIT TIME
: Follows the exit delay time for the assigned area. In the case of
multiple areas, it follows the longest period.
ENTRY TIME
: Follows the entry time for the assigned area. In the case of
multiple areas, it follows the longest period.
IN AND OUT DELAY TIME
: Follows both the exit time and entry time for the
assigned area.
FORCED ARM
: Follows forced arming with unready zones. This function is
useful for notifying that timer arming has been provided with a certain
number of not ready zones which are therefore automatically bypass from
arming.
CHIME
: Follows the chime alarm condition in a chime zone (this can be one or
more areas).
ZONE BYPASS
: Follows the existence of bypassed zones.
ZONE TAMPER
: Follows an alarm condition due to the activation of a wired or
wireless zone tamper (this can be one or more areas).
ALARM MEMORY
: Follows the addition to the memory of a siren alarm being
triggered. It remains active until the user reset.
READY
: Follows the zone ready condition. This can be one or more areas.
PART1 ALARM
: Follows an alarm condition due to an intrusion in partition 1
(this can be one or more areas). Follows alarm conditions such as the system
siren alarm output, but with alarm times for the area.
PART2 ALARM
: Follows an alarm condition due to an intrusion in partition 2
(this can be one or more areas). Follows alarm conditions such as the system
siren alarm output, but with alarm times for the area.
WATER LEAK
: Follows an alarm condition due to the activation of water
leaking.
FIRE
: Follows an alarm condition due to the activation of a wire or radio fire
zone (this can be one or more areas).
FIRE TROUBLE
: Follows an alarm condition due to the activation of a fire
failure (fire zone tamper).
PANIC
: Follows a panic alarm condition (this can be one or more areas).
ROBBERY
: Follows a robbery alarm condition (this can be one or more areas).
MEDICAL
: Follows a medical alarm condition (this can be one or more areas).
DURESS
: Follows a duress condition due to arming or disarming under
duress.
TIMER ERROR
: Follows a condition of failure arm operated by timer.
24H ZONE
: Follows an alarm conditions due to the activation of a 24-hour
zone (this can be one or more areas).