Web Operation Manual
24
Metering zone Figure 5-3
Configure the parameters. Step 2
Table 5-3 Metering zone parameter description
Parameter Description
Plate Light
When selecting On, you can turn ON backlight and frontlight according to scene
requirements to improve the backlight and frontlight image brightness.
Backlight
Frontlight
Measure
Mode
Global Measure
: Measure the brightness of the whole image area and
intelligently adjust the overall image brightness.
Partial Measure: Measure the brightness of sensitive areas and intelligently
adjust the overall image brightness. If the measured area becomes bright, then
the whole area becomes dark, and vice versa. Drag the mouse to select the
measured area and a yellow box displays over the video image. Drag the box
to a proper location, and then click Confirm to complete configuration.
Click Confirm. Step 3
5.1.1.4 Configuring Focus
Adjust the focus of the Camera.
Select Setting > Camera > Camera Attribute > Focus. Step 1