23-04 Occurrence
Array [10]
Option: Function:
Select which days the timed action
applies to. Specify working/non-working
days in:
Parameter 0-81 Working Days.
Parameter 0-82 Additional
Working Days.
Parameter 0-83 Additional Non-
Working Days.
[0] * All days
[1] Working days
[2] Non-working days
[3] Monday
[4] Tuesday
[5] Wednesday
[6] Thursday
[7] Friday
[8] Saturday
[9] Sunday
[10] Day 1 of month
[11] Day 2 of month
[12] Day 3 of month
[13] Day 4 of month
[14] Day 5 of month
[15] Day 6 of month
[16] Day 7 of month
23-04 Occurrence
Array [10]
Option: Function:
[17] Day 8 of month
[18] Day 9 of month
[19] Day 10 of month
[20] Day 11 of month
[21] Day 12 of month
[22] Day 13 of month
[23] Day 14 of month
[24] Day 15 of month
[25] Day 16 of month
[26] Day 17 of month
[27] Day 18 of month
[28] Day 19 of month
[29] Day 20 of month
[30] Day 21 of month
[31] Day 22 of month
[32] Day 23 of month
[33] Day 24 of month
[34] Day 25 of month
[35] Day 26 of month
[36] Day 27 of month
[37] Day 28 of month
[38] Day 29 of month
[39] Day 30 of month
[40] Day 31 of month
3.20.2 23-1* Maintenance
Wear and tear calls for periodic inspection and service of elements in the application, for example motor bearings, feedback
sensors, seals, and lters. With preventive maintenance, the service intervals may be programmed into the frequency
converter. The frequency converter gives a message when maintenance is required. 20 preventive maintenance events can
be programmed into the frequency converter.
Specify the following for each event:
Maintenance item (for example, motor bearings).
Maintenance action (for example, replacement).
Maintenance time base (for example, running hours, or a
specic date and time).
Maintenance time interval or the date and time of next maintenance.
NOTICE
To disable a preventive maintenance event, set the associated parameter 23-12 Maintenance Time Base to [0] Disabled.
Preventive maintenance can be programmed from the LCP, but use of the PC-based MCT 10 Set-up Software is
recommended.
Parameter Description Programming Guide
MG20OB02 Danfoss A/S © 05/2018 All rights reserved. 193
3 3

Table of Contents

Other manuals for Danfoss VLT AQUA Drive FC 202

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AQUA Drive FC 202 and is the answer not in the manual?

Danfoss VLT AQUA Drive FC 202 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AQUA Drive FC 202
CategoryDC Drives
LanguageEnglish

Related product manuals