READING FEATURES
89
9
DS6300-105-0XX (oscillating mirror) - Resolution: 0.30 mm/12 mils
4
2
0
6
(in)
0 8 14
(in)
10 12 16 18
0 20 25 30 35 40 45 50 55
(cm)
25
20
15
10
0
(cm)
5
-5
-10
-15
-20
-25
8
10
-8
-10
-6
-4
-2
60 65
2220 24 26
Focus
Position = 0
-30
-12
30
12
70 75 80 85
30 28 32 34
Focus
Position = 40
Focus
Position = 60
Figure 108 - Oscillating Mirror Model 0.30 mm / 12 mils Reading Diagram
CONDITIONS
Code = Interleaved 2/5 or Code 39
PCS = 0.90
Pitch angle = 0°
Skew angle = 10° - 20°
Tilt angle = 0°
Note: (0,0) is the center of the laser beam output window.