DS6300 REFERENCE MANUAL
18
2
The Tilt angle is represented by the value T in Figure 20.
Figure 20 - "Tilt" Angle
2.3.1 16° Skew Positioning
The DS6300 scanner is mounted on the ST-237 106° mounting bracket (see Figure 9) which
guarantees
a built-in Skew angle (S in the figure below) of 16° with respect to the frame
plane (typically the Skew angle should be between 10° - 20°). This avoids the direct
reflection of the laser light emitted by the scanner. Furthermore, the bracket guides allow
adjusting the Tilt angle (T in the figure below, which is typically 0°) for the best scanner
orientation:
Figure 21 – Standard Installation
T
T
Conveyor Direction
S