Removal and Replacement
4-18
Printhead
Assembly
Inner
Bearing Plate
Screw
Assist
Roller
Platen
Block
4. Disconnect the Drive Motor Cable from the Power Supply PCB.
5. Remove the two Screws and Lock Washers that secure the Drive Motor then carefully
remove the Drive Motor.
Drive
Motor
Screws
Lock
Washers
Drive
Motor Cable
Isolator
Installation:
1. Carefully insert the motor’s gear into the drive gear train, rotating the Drive Motor so
that it rests flush against the Isolator, with gears meshed, aligned to the screw holes.

Table of Contents

Other manuals for Datamax M-Class Mark II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datamax M-Class Mark II and is the answer not in the manual?

Datamax M-Class Mark II Specifications

General IconGeneral
Media SensorAdjustable reflective and transmissive sensors
Print MethodThermal Transfer
Print Resolution203 dpi
Memory8 MB Flash, 16 MB SDRAM
Interface OptionsUSB, Serial, Ethernet, Parallel
Media TypeRoll-fed, die-cut, continuous, fan-fold, tags, ticket stock
Media Width1.0 in (25.4 mm) to 4.65 in (118 mm)
Media Thickness0.0025 in (0.0635 mm) to 0.010 in (0.254 mm)
Media Roll Diameter8 inches (203 mm) max
Ribbon Width1 to 4.33 inches (25.4 to 110 mm)
Ribbon Length1968 ft (600 m)
Ribbon Core1 inch (25.4 mm)
Label Width Range1.0 in (25.4 mm) to 4.65 in (118 mm)
Label Length Range0.25 to 39 inches (6.35 to 991 mm)

Related product manuals