EasyManua.ls Logo

Dell EMC PowerEdge R740xd2 - Removing Expansion Card from the Expansion Card Riser

Dell EMC PowerEdge R740xd2
197 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 83. Installing the ller bracket
NOTE
: Filler brackets must be installed over empty expansion card slots to maintain FCC certication of the system.
The brackets also keep dust out of the system and aid in proper cooling and airow inside the system.
Next step
1 Replace the expansion card on the system board.
Removing expansion card from the expansion card riser
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Power o the system and all attached peripherals.
3 Disconnect the system from the electrical outlet, and disconnect the peripherals.
4 Open the drive bays, remove all drives, and then close the drive bays.
5 Remove the power supply units.
6 Remove the system from the rack and place it on an ESD work bench. For more information, see the Rail Installation Guide available at
www.dell.com/poweredgemanuals.
7 Remove the system cover.
8 Remove the air shroud.
9 If installed, remove the rear drive cage.
10 Remove the expansion card riser from the system.
11 When removing a card from low prole, full height X1, or buttery riser, ensure that the PCIe card holder latch is closed.
Installing and removing system components