Loading...
Figure 54. Installing bay 2 backplane brackets
Next steps
1 Place the system into the rack. For more information, see the Rail Installation Guide available at www.dell.com/poweredgemanuals.
2 Open the drive bays, install all drives, and then close the drive bays.
3 Install the power supply units.
4 If removed, install the front bezel.
5 Follow the procedure listed in After working inside your system.
Bay intrusion switch
Removing bay intrusion switch
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3 If installed, remove the front bezel.
4 Open the drive bays.
5 Remove the drive bay 1 bracket.
Steps
1 Disconnect the intrusion switch cable connected to the backplane of drive bay 1.
2 Using a Phillips #1 screwdriver, remove the screws securing the intrusion switch to the intrusion switch slot.
3 Disengage the intrusion switch from the intrusion switch slot and remove it from the system.