Figure 56. Installing the bay intrusion switch
Next steps
1 Install the drive bay 1 bracket.
2 Close the drive bays.
3 If removed, install the front bezel.
4 Follow the procedure listed in After working inside your system.
Rear drive cage
Removing the rear drive cage
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Power o the system and all attached peripherals.
3 Disconnect the system from the electrical outlet, and disconnect the peripherals.
4 Open the drive bays, remove all drives, and then close the drive bays.
5 Remove the power supply units.
6 Remove the system from the rack and place it on an ESD work bench. For more information, see the Rail Installation Guide available at
www.dell.com/poweredgemanuals.
7 Remove the system cover.
8 Remove the air shroud.
9 Remove the rear drives.
10 Disconnect all the cables from the rear drive backplane.