9 Remove the air shroud.
10 Remove the internal PERC card.
11 Disconnect all cables connected to the system board.
Steps
1 Open the blue release clip and disconnect the right control panel cable from the system board.
2 Release the cable from the right rack ear cable clips and push the cable connector through the side of the fan cage.
NOTE: Ensure that you note the routing of the cables as you remove them from the system board. Route the cables
properly when you replace them to prevent the cables from being pinched or crimped.
3 Push bay 2 into the chassis and release the cable from the right rack ear cable clips.
Figure 138. Removing the control panel cable
4 Using Phillips #1 screwdriver, remove the screws that secure the right control panel assembly to the system.
5 Holding by the sides, remove the right control panel assembly away from the system.
Installing and removing system components
169