670 Configuring IPv6
Figure 10-31. NSF OSPFv3 Summary
Support Mode — Enables or disables OSPFv3 to perform graceful restarts. The following options are
available:
PlannedOSPFv3 will perform a graceful restart for planned restarts. A planned restart is a
failover initiated by the administrator (see
"Enabling and Disabling NSF
" on page 258).
AlwaysOSPFv3 will perform a graceful restart for all planned and unplanned warm restart
events.
DisableOSPFv3 will not perform graceful restarts.
Restart Interval — The grace period during which a neighboring router will be in the helper state after
receiving notice that the management unit is performing a graceful restart.
Restart Status — Displays the restart status of OSPFv3 Helper feature. The possible values are:
–Not Restarting
–Planned Restart
Unplanned Restart
Restart Age (secs) — Displays the ammount of time since the last restart occured.
Restart Exit Reason — Displays how the master unit on the stack last started up. The possible values
are:
Not AttemptedGraceful restart has not been attempted.
In ProgressRestart is in progress.
CompletedThe previous gracefull restart completed successfully.
Timed OutThe previous graceful restart timed out.
Topology ChangedThe previous graceful restart terminated prematurely because of a topology
change.
If you change the Support Mode, click Submit to save your change.