Conguration Number of
processors
Heatsink Processor/DIMM
blank
DIMM
blanks
Type of air
shroud
Fan
PowerEdge
R740xd with
mid bay
1 One 1U high performance
heat sink
Required Required Not required Six high
performance
fans
PowerEdge
R740xd with
mid bay
2 Two 1U high performance
heat sink
Not required Required Not required Six high
performance
fans
PowerEdge
R740xd with
GPU
2 Two 1U high performance
heat sink
Not required Not
required
GPU air shroud Six high
performance
fans
Ambient temperature limitations
The following table lists congurations that require ambient temperature less than 35°C.
NOTE: The ambient temperature limit must be adhered to ensure proper cooling and to avoid excess CPU throttling, which may
impact system performance.
Table 31. Conguration based ambient temperature restrictions
System Backplane CPU Thermal
Design Power
(TDP)
CPU heat sink Fan type GPU Ambient
restriction
PowerEdge
R740xd
12 x 3.5 inch SAS/
SATA + 4 x 2.5 inch
NVMe + 2 x 3.5
inch
70 W, 85 W, 105
W, 115 W, 125 W,
130 W, 140 W, 150
W, 165 W
1U high
performance
High performance
fan
N/A 30°C
12 x 3.5 inch SAS/
SATA + 4 x 2.5 inch
NVMe + 2 x 3.5
inch
150 W/8 core,
165 W/12 core,
200 W, 205 W
1U high
performance
High performance
fan
N/A 25°C
12 x 3.5 inch SAS/
SATA + 4 x 3.5 inch
+ 2 x 3.5 inch
150 W/8 core,
165 W/12 core,
200 W, 205 W
1U high
performance
High performance
fan
N/A 25°C
24 x 2.5 inch SAS/
SATA + 4 x 2.5 inch
+ 4 x 2.5 inch
150 W/8 core,
165 W/12 core,
200 W, 205 W
1U high
performance
High performance
fan
N/A 25°C
24 x 2.5 inch SAS/
SATA/NVMe with
adapter PERC
H740P
150 W/8 core,
165 W/12 core,
200 W, 205 W
1U high
performance
High performance
fan
≥1 double-width/
single-width
30°C
Particulate and gaseous contamination specications
The following table denes the limitations that help avoid any equipment damage or failure from particulate and gaseous contamination. If
the levels of particulate or gaseous pollution exceed the specied limitations and result in equipment damage or failure, you may need to
rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer.