EXEC Privilege mode
show system brief
Display the same information in show system, but only for the specied unit.
EXEC Privilege mode
show system stack-unit
Display topology and stack link status for the entire stack.
EXEC Privilege mode
show system stack-ports [status | topology]
Examples of the show system Commands
Display information about a switch stack using the show system command.
The following is an example of the show system command to view the stack details.
Dell#show system
Stack MAC : 34:17:eb:f2:94:c4
Reload-Type : normal-reload [Next boot : normal-reload]
-- Unit 1 --
Unit Type : Management Unit
Status : online
Next Boot : online
Required Type : S4048-ON - 54-port TE/FG (SK-ON)
Current Type : S4048-ON - 54-port TE/FG (SK-ON)
Master priority : 14
Hardware Rev : 2.0
Num Ports : 72
Up Time : 33 min, 51 sec
Dell Networking OS Version : 1-0(0-5005)
Jumbo Capable : yes
POE Capable : no
FIPS Mode : disabled
Burned In MAC : 34:17:eb:f2:94:c4
No Of MACs : 3
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
---------------------------------------------------------------------------
1 1 up UNKNOWN up 10704
1 2 absent absent 0
-- Fan Status --
Unit Bay TrayStatus Fan1 Speed Fan2 Speed
------------------------------------------------------------------------------------
1 1 up up 10134 up 10031
1 2 up up 10031 up 10031
1 3 up up 10031 up 10031
Speed in RPM
-- Unit 2 --
Unit Type : Standby Unit
Status : online
Next Boot : online
Required Type : S4048-ON - 54-port TE/FG (SK-ON)
Current Type : S4048-ON - 54-port TE/FG (SK-ON)
Master priority : 10
Hardware Rev : 2.0
Num Ports : 72
Up Time : 33 min, 52 sec
Dell Networking OS Version : 1-0(0-5005)
Jumbo Capable : yes
POE Capable : no
Stacking
911

Table of Contents