35 XTLtouch Series Programming Guide | Digital Monitoring Products
MESSAGE TO TRANSMIT
You can send two report types to the receiver: Alarm and Trouble. These are represented
by the characters A and T. Press any select area to display the zone report options.
ALARM - Selecting A allows an alarm report to be sent to the receiver and the wireless
siren output to activate according to zone type. See the Bell Action section. The zone
name appears in the panel’s alarmed zones status lists.
TROUBLE - Selecting T allows a trouble report to be sent to the receiver and the zone
name to appear in the panel’s alarmed zones status lists.
LOCAL - When you select L, an alarm report is NOT sent to the receiver. The bell output
still activates according to zone type and the zone name appears in the panel’s alarmed
zones status lists.
– (dash) - When you select – , reports are NOT sent to the receiver. The wireless siren
output does not activate and there is no display in the panel’s alarmed zones status list.
Only the programmed Output Number activates.
OUTPUT NUMBER
You can specify any of the outputs on the XTLtouch to be activated by a zone condition.
The output can be activated regardless of the report to transmit or whether or not the
zone is programmed as local. An output activated by a non-24-hour armed zone is
turned o when the zone’s area is disarmed by a user.
To enter an Output Number, press any select area followed by the output number 51-54,
61-64, or F1-F20. Press CMD.
OUTPUT ACTION
Entering an Output Number displays this option that allows you to assign an output
action. A description of the available output actions is given below:
STEADY - The output is turned on and remains on until the area is disarmed, an output
cuto time expires, or the output is reset from the keypad User Menu.
PULSE - The output alternates one second on and one second o until the area is
disarmed, an output cuto time expires, or the output is reset from the keypad User
Menu.
MOMENTARY - The output is turned on only once for one second.
FOLLOW - The output is turned on and remains on while the zone is in an o normal, or
bad condition. When the zone restores, the output is turned o.
After you have selected the Message To Transmit, the display prompts you for the same
three selections for Disarmed Short, Armed Open, and Armed Short conditions. If the
zone is a 24-hour type, only the Armed Open and Armed Short conditions are displayed.
When you have programmed all of the zone conditions, the Swinger Bypass selection is
then dis played.
MSG: TROUBLE
A T L -
OUTPUT NO: 0
ACTION:
STD PLS MOM FOLW