36 XTLtouch Series Programming Guide | Digital Monitoring Products
SWINGER BYPASS
Selecting YES allows the zone to be swinger bypassed by the panel according to
the programming in Swinger Bypass Trips and Reset Swinger Bypass. The Bypassed
zone displays in the keypad Status List. Selecting NO disables swinger bypassing for this
zone.
How it works
If within one hour, a zone trips the total number of times as specified in Swinger Bypass
Trips, the panel bypasses it until the following conditions occur; the area in which the
zone is assigned is disarmed, the zone is manually reset through the Bypass Zones
keypad User Menu function, the zone remains normal for one hour and the Reset
Swinger Bypass is YES.
If the zone trips fewer than the specified times within one hour of the first trip, the
bypass trip counter returns to 0 (zero) and the process must be repeated.
A report of the swinger bypass is sent to the receiver if Bypass Reports is YES.
PREWARN ADDRESS
Option is only shown for an Exit zone.
At the start of the entry delay, all keypad addresses dis play ENTER CODE:-. If you want
the prewarn to sound at all addresses, leave the default as shown.
To delete an address, press the matching number on the keypad. To disable prewarning
at all keypads, press a top row key to clear the addresses shown. Press CMD when the
address selection is com plete.
Note: The prewarn tone stops at the keypad when the first digit of a user code is
entered. If, within five seconds, a valid user code is not entered or an invalid user code
is entered, the prewarn tone begins sounding again. Fifteen seconds must elapse before
entering a digit silences the prewarn tone again.
CHIME
Option is only shown for Night, Exit, and Instant zones. Select either NONE, DB
(doorbell), DESC (descend), or ASC (ascend) to assign that tone to a zone. Default is
DOORBELL for Exit zones and NONE for Night zones.
ENTRY DELAY
Option is only shown for an Exit zone. Select the entry delay timer for this
zone. Entry delay timers 1 and 2 are programmed in Entry Delay in the System Options
menu.
SWGR BYP NO YES
PREWARN: 12345
CHIME: DOORBELL
NONE DB DESC ASC
ENTRY DELAY: 1