Turn key switch (3) to ―ON‖ position, its terminals ―BR‖ and ―B‖ are connected, power relay (6) acts,
electric current coming from storage battery (2) goes through fuse box (4), power relay (6), charging
indication light (8) and excitation resistance (9) and reaches ―D+‖ terminal of generator (5), earth connected
and forms a circuit, charging indication light (8) is on to warn and supplies excitation electric current for
generator (5). After engine is started, generator (5) starts charging. Electric current comes from terminal
―B+‖ of generator (5), goes through fuse box (4) and reaches storage battery (2). Charging indication light (8)
is off.
Generator (5) also supplies power to other electrical parts through fuse box (4) and power relay (6).