Maintenance - Lubricants and symbols
4812158801_E.pdf2018-04-03
Maintenance - Lubricants and symbols
Always use high-quality lubricants and the
amounts recommended. Too much grease or
oil can cause overheating, resulting in rapid
wear.
Always use high-quality lubricants and the
amounts recommended. Too much grease or
oil can cause overheating, resulting in rapid
wear.
Fluid volumes
liters gallon (U.S.)
Fluid volumes
liters gallon (U.S.)
Hydraulic reservoir 120 31,7Hydraulic reservoir 120 31,7
Hydraulic system 25 6,6Hydraulic system 25 6,6
Pump gear 3,1 0,82Pump gear 3,1 0,82
DrumDrum
- Drum 53 14- Drum 53 14
- Gear box 3 0,79- Gear box 3 0,79
Diesel engineDiesel engine
- Oil 15,7 4,1- Oil 15,7 4,1
- Coolant 28 7,4- Coolant 28 7,4
Other fuel and lubricants are required when
operating in areas with extremely high or
extremely low ambient temperatures. See the
‘Special instructions’ chapter, or consult
Dynapac.
Other fuel and lubricants are required when
operating in areas with extremely high or
extremely low ambient temperatures. See the
‘Special instructions’ chapter, or consult
Dynapac.
ENGINE OIL Air temperature -15°C - +50°C
(5°F-122°F)
Dynapac engine oil 200 P/N 4812161855 (5 liters),
P/N 4812161856 (20 liters)
ENGINE OIL Air temperature -15°C - +50°C
(5°F-122°F)
Dynapac engine oil 200 P/N 4812161855 (5 liters),
P/N 4812161856 (20 liters)
HYDRAULIC FLUID Air temperature -15°C - +50°C
(5°F-122°F)
Dynapac hydraulic 300 P/N 4812161868 (20 liters),
P/N 4812161869 (209
liters)
HYDRAULIC FLUID Air temperature -15°C - +50°C
(5°F-122°F)
Dynapac hydraulic 300 P/N 4812161868 (20 liters),
P/N 4812161869 (209
liters)
Air temperature over +40°C
(104°F)
Shell Tellus S2 V100Air temperature over +40°C
(104°F)
Shell Tellus S2 V100
BIOLOGICAL
HYDRAULIC FLUID,
PANOLIN
Air temperature -10°C - +35°C
(14°F-95°F)
When it leaves the factory, the
machine may be filled with
biologically degradable fluid.
The same type of fluid must be
used when changing or topping
up.
PANOLIN HLP Synth 46
(www.panolin.com)
BIOLOGICAL
HYDRAULIC FLUID,
PANOLIN
Air temperature -10°C - +35°C
(14°F-95°F)
When it leaves the factory, the
machine may be filled with
biologically degradable fluid.
The same type of fluid must be
used when changing or topping
up.
PANOLIN HLP Synth 46
(www.panolin.com)
DRUM OIL Air temperature -15°C - +40°C
(5°F-104°F)
Dynapac Gear oil 300,
P/N 4812030756 (5 liters),
P/N 4812030117 (20 liters),
P/N 4812031574 (209
liters)
DRUM OIL Air temperature -15°C - +40°C
(5°F-104°F)
Dynapac Gear oil 300,
P/N 4812030756 (5 liters),
P/N 4812030117 (20 liters),
P/N 4812031574 (209
liters)
GREASE Lubrication points in addition to
articulated joint
Dynapac Roller Grease
P/N 4812030096 (0.4kg)
GREASE Lubrication points in addition to
articulated joint
Dynapac Roller Grease
P/N 4812030096 (0.4kg)
61