Maintenance - 1000h
4812158801_E.pdf 2018-04-03
Hydraulic fluid reservoir - Draining
Fig. Hydraulic reservoir
1. Drain plug
1
Condensate in the hydraulic reservoir is drained via
the plug (1).
Be very careful during draining. Do not drop the
plug or else all the hydraulic fluid will flow out.
Be very careful during draining. Do not drop the
plug or else all the hydraulic fluid will flow out.
Drainage must be performed when the roller has been
stationary for an extended period, e.g. after being
stationary overnight.
Drain as
follows:
- Place a container under the plug (1).
- Remove the plug.
- Drain the condensate until pure hydraulic fluid runs
out.
- Refit the plug again.
Collect the condensate and accompanying
hydraulic fluid and deliver to environmentally
correct handling.
Collect the condensate and accompanying
hydraulic fluid and deliver to environmentally
correct handling.