Model 200i and 250i Motorcycle Dynamometer Installation Guide
APPENDIXB
Locations Using 50 Hz Power (Locations Other than North America and Japan)
B-8
INSTALLING THE WALL RECEPTACLE
The wall receptacle is a single 240 volt 30A dedicated circuit with a ground.
The cable carrying the power to this receptacle should be 4.0 mm
2
(ten gauge) or
larger. Check with local building codes for the correct size.
1 Connect one of the 240V legs to the N terminal (white).
2 Connect the other 240V leg to the L terminal (no color).
3 Connect the ground conductor to the green terminal.
Figure B-2: Wire the Wall Receptacle
N terminal
(white)
L terminal
ground terminal
(green)