2019.07.11
© 2017 Eaton. All rights reserved
114
TRSM0940 Service Procedures | MHP/MXP/VHP/VXP Auxiliary Countershaft Installation
11. Apply Eaton Sealant #71205 or equivalent to the retain-
ing cap screws, and install the six (6) cap screws in the
non
-chamfered holes. Torque to 35-45 lb-ft
(47.45-61.01N•m).
12. Install the Auxiliary Countershaft
Bearing Races.
13. Install
each Auxiliary Countershaft Retaining Strap with
2- 3/8” NC x 1” NC and 1 3/8” NC x 2-1/2” clean cap
screws.
Note: D
o not use an air gun on strap bolts. Tighten by
hand until cap screws are snug