Main Case Main Shaft Disassembly with Low Force Gearing | Service Procedures TRSM0940
Main Case Main Shaft Disassembly with Low
Force Gearing
1. Remove the front (4th and 5th Gear) Sliding Clutch
from the Main Shaft
2. From the rear
of the Main Shaft, remove the Reverse
Gear.
3. Remo
ve the 1st and Reverse Sliding Clutch and hub
4. Remove
Snap Ring that retains the key.