TRSM0940 Service Procedures | Main Case Main Shaft Disassembly with Low Force Gearing
5. Remove the key from the Main Shaft keyway.
Note: When removing
no-burn washers or spacers,
note their location on the Main Shaft to facilitate reas-
sembly. Keep each washer with the corresponding gear
it
was mated against.
6. Remove the 1st
stepped no-burn washer from the
Main Shaft.
Note: There
are two types of washers used on the Main
Shaft. The stepped washers (left) fit between gears and
sliding clutches with the stepped edge facing the slid-
ing clutch. The flat no-burn washers fit