Main Case Main Shaft Assembly with Low Force Gearing | Service Procedures TRSM0940
7. Install the stepped washer. Rotate the washer and push
the air line through.
8. Install
2nd Gear and the no-burn washer. Rotate the
no-burn washer and push the air line through.
9. Install
1st gear and stepped washer. Rotate the
no-burn washer and push the air line through.
10. In
stall the Main Shaft Key through the slot were the
5/32” air line sits by pushing the air line out with the
key until it is seated against the role pin.